Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/69929
Título: | Fluoride removal from natural volcanic underground water by an electrocoagulation process: Parametric and cost evaluations | Autores/as: | Mena, V. F. Betancor-Abreu, A. González, S. Delgado, S. Souto, R. M. Santana, J. J. |
Clasificación UNESCO: | 3303 ingeniería y tecnología químicas | Palabras clave: | Aluminum Electrodes Electrocoagulation Process Fluoride Removal Water Treatment |
Fecha de publicación: | 2019 | Publicación seriada: | Journal of Environmental Management | Resumen: | Excessive fluoride content in groundwater can cause serious risks to human health, and sources of groundwater intended for human consumption should be treated to reduce fluoride concentrations down to acceptable levels. In the particular case of the island of Tenerife (Canary Islands, Spain), the water supply comes mainly from aquifers of volcanic origin with a high content of fluorides that make them unacceptable for human consumption without prior conditioning treatment. The treatments that generate a high rejection of water are not acceptable because water is a scarce natural resource of high value. An electrocoagulation process was investigated as a method to treat natural groundwater from volcanic soils containing a hazardously high fluoride content. The operating parameters of an electrocoagulation reactor model with parallel plate aluminum electrodes were optimized for batch and continuous flow operations. In the case of the batch operation, acidification of the water improved the removal efficiency of fluoride, which was the highest at pH 3. However, operation at the natural pH of the water achieved elimination efficiencies between 82 and 92%, depending on the applied current density. An optimum current density of 5 mA/cm2 was found in terms of maximum removal efficiency, and the kinetics of fluoride removal conformed to pseudo-second-order kinetics. In the continuous-flow operation, with the optimal residence time of 10 min and a separation of 0.5 cm between the electrodes, it was observed that the current density that would be applied would depend on the initial concentration of fluoride in the raw water. Thus, an initial fluoride concentration of 6.02 mg/L required a current density >7.5 mA/cm2 to comply with the legal guidelines in the product water, while for an initial concentration of 8.98 mg/L, the optimal current density was 10 mA/cm2. Under these operating conditions, the electrocoagulation process was able to reduce the fluoride concentration of natural groundwater to below 1.5 mg/L according to WHO guidelines with an operating cost between 0.20 and 0.26 €/m3 of treated water. | URI: | http://hdl.handle.net/10553/69929 | ISSN: | 0301-4797 | DOI: | 10.1016/j.jenvman.2019.05.147 | Fuente: | Journal of Environmental Management[ISSN 0301-4797],v. 246, p. 472-483 |
Colección: | Artículos |
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.