Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/50540
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Ben Abdallah, Mariem | en_US |
dc.contributor.author | Malek, Jihene | en_US |
dc.contributor.author | Tourki, Rached | en_US |
dc.contributor.author | Monreal, Julio Esclarin | en_US |
dc.contributor.author | Krissian, Karl | en_US |
dc.date.accessioned | 2018-11-24T16:50:18Z | - |
dc.date.available | 2018-11-24T16:50:18Z | - |
dc.date.issued | 2013 | en_US |
dc.identifier.isbn | 978-1-4673-6459-1 | en_US |
dc.identifier.isbn | 978-1-4673-6457-7 | - |
dc.identifier.isbn | 978-1-4673-6458-4 | - |
dc.identifier.uri | http://hdl.handle.net/10553/50540 | - |
dc.description.abstract | For several years, a lot of studies have been done on image analysis and image understanding. In medical imaging, the retinal images are usually corrupted by noise in its acquisition or transmission. There are various sources of noise inherent in the use of CCD's (Charge Coupled Device) and other external effects such as space radiation (cosmic rays) can have negative effects on the obtained data. In the context of retinal image denoising, most of algorithms assumes the noise is additive and independent of the RGB image data, and is also a Gaussian sample. However, the type and level of the noise generated by digital cameras are unknown if we don't have enough informations about the sensor and circuitry of a digital camera. Therefore, these approaches cannot effectively recover the ”true” signal (or its best approximation) from these noisy acquired observations. Thus, modeling noise in retinal images is an important and huge step before any processing task. The purpose of this paper is to explore CCD's and understand an algorithm for estimating the noise model in fundus image. | en_US |
dc.language | eng | en_US |
dc.source | 2013 10th International Multi-Conference on Systems, Signals and Devices, SSD 2013 (6564014) | en_US |
dc.subject | 1203 Ciencia de los ordenadores | en_US |
dc.subject.other | CCD camera | en_US |
dc.subject.other | Fundus imagex | en_US |
dc.subject.other | Noise statistics | en_US |
dc.subject.other | Modeling noise | en_US |
dc.title | Automatic estimation of the noise model in fundus images | en_US |
dc.type | info:eu-repo/semantics/conferenceObject | es |
dc.type | ConferenceObject | es |
dc.relation.conference | 2013 10th International Multi-Conference on Systems, Signals and Devices, SSD 2013 | |
dc.identifier.doi | 10.1109/SSD.2013.6564014 | |
dc.identifier.scopus | 84883129125 | - |
dc.identifier.isi | 000326445400017 | - |
dc.contributor.authorscopusid | 36450046200 | - |
dc.contributor.authorscopusid | 16203443800 | - |
dc.contributor.authorscopusid | 6603352243 | - |
dc.contributor.authorscopusid | 7003781267 | - |
dc.contributor.authorscopusid | 6602218913 | - |
dc.identifier.issue | 6564014 | - |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Actas de congresos | en_US |
dc.date.coverdate | Septiembre 2013 | |
dc.identifier.conferenceid | events121481 | |
dc.identifier.ulpgc | Sí | es |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.event.eventsstartdate | 18-03-2013 | - |
crisitem.event.eventsenddate | 21-03-2013 | - |
crisitem.author.dept | GIR IUCES: Centro de Tecnologías de la Imagen | - |
crisitem.author.dept | IU de Cibernética, Empresa y Sociedad (IUCES) | - |
crisitem.author.orcid | 0000-0003-1339-8700 | - |
crisitem.author.parentorg | IU de Cibernética, Empresa y Sociedad (IUCES) | - |
crisitem.author.fullName | Esclarín Monreal,Julio | - |
Colección: | Actas de congresos |
Citas SCOPUSTM
12
actualizado el 17-nov-2024
Visitas
110
actualizado el 14-sep-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.