Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/76295
Título: | Fine-needle percutaneous transhepatic parenchymal portal venography by using carbon dioxide: a pilot study in pigs | Autores/as: | Sun, F Hernandez, J Crisostomo, V Pineda, LF Lima, JR Uson, J Maynar Moliner, Manuel |
Clasificación UNESCO: | 32 Ciencias médicas 320111 Radiología |
Palabras clave: | Digital Subtraction Angiography Wedged Hepatic Venography Venous System Co2 Liver, et al. |
Fecha de publicación: | 2003 | Publicación seriada: | European Radiology | Resumen: | Our purpose was to evaluate the feasibility and safety of carbon dioxide (CO2) in fine-needle percutaneous transhepatic parenchymal portal venography and its potential clinical applications. Three Belgian landrace pigs received fine-needle percutaneous transhepatic parenchymal portal venography by using CO2 as a contrast agent. Under fluoroscopic and B-mode ultrasonic guidance, right or left lobe of liver was punctured with a 22-G Chiba needle, through which CO2 was injected with a dedicated CO2 injector at injection rate of 20 ml/s for 20 ml, 40 ml/s for 40 ml, 40 ml/s for 60 ml, and 40 ml/s for 80 ml, respectively. The portal venograms were obtained by use of digital subtraction angiography (DSA) system with animal in supine position. In one pig transarterial portal venography was performed, in addition, using iodinated contrast agent. The portal vein was visualized in each run of venography. Optimal images of portal tree structure up to four-order branches were obtained in all those with CO2 injection rate of 40 ml/s, which appeared much better in quality than those obtained by cranial mesenteric arteriography with iodinated contrast agent. No extravasation of CO2, liver laceration, or any other complication occurred during the procedures. The technique we proposed demonstrated optimal portography, which appeared to be safe, minimally invasive, less time-consuming, cost-effective, and easy to perform, with great potential in clinical applications. | URI: | http://hdl.handle.net/10553/76295 | ISSN: | 0938-7994 | DOI: | 10.1007/s00330-002-1386-2 | Fuente: | European Radiology [ISSN 0938-7994], v. 13 (2), p. 244-250, (Febrero 2003) |
Colección: | Artículos |
Citas SCOPUSTM
5
actualizado el 15-dic-2024
Citas de WEB OF SCIENCETM
Citations
4
actualizado el 15-dic-2024
Visitas
57
actualizado el 09-dic-2023
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.