Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/72256
Título: | Behavior of two titanium alloys in simulated body fluid | Autores/as: | Mirza Rosca, Julia Claudia Herrera Santana, Eladio D. Drob, S. Martínez Ortigosa, Agurtzane |
Clasificación UNESCO: | 330307 Tecnología de la corrosión 331208 Propiedades de los materiales |
Palabras clave: | Titanium alloys Corrosion resistance Ti Ti-6Al-7Nb Ti-6Al-4Fe |
Fecha de publicación: | 2011 | Publicación seriada: | Materials Research Society Symposium - Proceedings | Conferencia: | 2011 MRS Spring Meeting | Resumen: | Titanium possesses an excellent corrosion resistance in biological environments because the titanium dioxide formed on its surface is extremely stable. When aluminium and vanadium are added to titanium in small quantities, the alloy achieves considerably higher tensile properties than of pure titanium and this alloy is used in high stress-bearing situations. But these metals may also influence the chemostatic mechanisms that are involved in the attraction of biocells. V presence can be associated with potential cytotoxic effects and adverse tissue reactions. The alloys with aluminium and iron or with aluminium and niobium occur to be more suitable for implant applications: it possesses similar corrosion resistance and mechanical properties to those of titanium-aluminium-vanadium alloy; moreover, these alloys have no toxicity. In this paper, pure Ti, Ti-6Al-7Nb and Ti-6Al-4Fe with a nanostructured surface were studied. Data about mechanical behavior are presented. The mechanical behavior was determined using optical metallography, tensile strength and Vickers microhardness. For the electrochemical measurements a conventional three-electrode cell with a Pt grid as counter electrode and saturated calomel (SCE) as reference electrode was used. AC impedance data were obtained at open circuit potential using a PAR 263A potentiostat connected with a PAR 5210 lock-in amplifier. The ESEM and EDAX observation were carried out with an environmental scanning electronic microscope Fei XL30 ESEM with LaB6-cathode attached with an energy-dispersive electron probe X-ray analyzer (EDAX Sapphire). After 3 days of immersion in simulated body fluid the nucleation of the bone growth was observed on the implant surface. It resulted that the tested oxide films presented passivation tendency and a very good stability and no form of local corrosion was detected. The mechanical data confirm the presence of an outer porous passive layer and an inner compact and protective passive layer. EIS confirms the mechanical results. The thicknesses of these layers were measured. SEM photographs of the surface and EDX profiles for the samples illustrate the appearance of a microporous layer made up of an alkaline titanate hydrogel. The apatite-forming ability of the metal is attributed to the amorphous sodium titanate that is formed on the metal during the surface treatment. The results emphasized that the surface treatment increases the passive layer adhesion to the metal surface and improves the biocompatibility of the biomedical devices inducing the bone growth on the implant surface. © 2011 Materials Research Society. | URI: | http://hdl.handle.net/10553/72256 | ISBN: | 9781627482004 | ISSN: | 0272-9172 | DOI: | 10.1557/opl.2011.1137 | Fuente: | Materials Research Society Symposium Proceedings [ISSN 0272-9172], v. 1355, p. 22-27 |
Colección: | Actas de congresos |
Visitas
122
actualizado el 31-dic-2023
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.