Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/55391
Título: | Reproducibility andrRepeatability of five different technologies for Bar velocity measurement in resistance training | Autores/as: | Courel-Ibáñez, Javier Martínez-Cava, Alejandro Morán-Navarro, Ricardo Escribano-Peñas, Pablo Chavarren-Cabrero, Javier González-Badillo, Juan José Pallarés, Jesús G |
Clasificación UNESCO: | 241106 Fisiología del ejercicio | Palabras clave: | Exercise testing Monitoring Standard error of measurement Strength performance Validity, et al. |
Fecha de publicación: | 2019 | Publicación seriada: | Annals of Biomedical Engineering | Resumen: | This study aimed to analyze the agreement between five bar velocity monitoring devices, currently used in resistance training, to determine the most reliable device based on reproducibility (between-device agreement for a given trial) and repeatability (between-trial variation for each device). Seventeen resistance-trained men performed duplicate trials against seven increasing loads (20-30-40-50-60-70-80 kg) while obtaining mean, mean propulsive and peak velocity outcomes in the bench press, full squat and prone bench pull exercises. Measurements were simultaneously registered by two linear velocity transducers (LVT), two linear position transducers (LPT), two optoelectronic camera-based systems (OEC), two smartphone video-based systems (VBS) and one accelerometer (ACC). A comprehensive set of statistics for assessing reliability was used. Magnitude of errors was reported both in absolute (m s-1) and relative terms (%1RM), and included the smallest detectable change (SDC) and maximum errors (MaxError). LVT was the most reliable and sensitive device (SDC 0.02-0.06 m s-1, MaxError 3.4-7.1% 1RM) and the preferred reference to compare with other technologies. OEC and LPT were the second-best alternatives (SDC 0.06-0.11 m s-1), always considering the particular margins of error for each exercise and velocity outcome. ACC and VBS are not recommended given their substantial errors and uncertainty of the measurements (SDC > 0.13 m s-1). | URI: | http://hdl.handle.net/10553/55391 | ISSN: | 0090-6964 | DOI: | 10.1007/s10439-019-02265-6 | Fuente: | Annals of Biomedical Engineering [ISSN 0090-6964], p. 1-16 | URL: | https://api.elsevier.com/content/abstract/scopus_id/85064450478 |
Colección: | Artículos |
Citas SCOPUSTM
122
actualizado el 15-dic-2024
Citas de WEB OF SCIENCETM
Citations
115
actualizado el 15-dic-2024
Visitas
45
actualizado el 09-sep-2023
Descargas
476
actualizado el 09-sep-2023
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.