Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/45840
Título: Evaluation of a low-dose synthetic adrenocorticotropic hormone stimulation test in clinically normal dogs and dogs with naturally developing hyperadrenocorticism
Autores/as: Kerl, Marie E.
Peterson, Mark E.
Wallace, Melissa S.
Melián Limiñana, Carlos 
Kemppainen, Robert James
Clasificación UNESCO: 310908 Farmacología
240118 Mamíferos
Palabras clave: Familial Hypoadrenocorticism
Adrenal Cortex Hyperfunction
Trilostane
Animal experiment
Corticotropin, et al.
Fecha de publicación: 1999
Editor/a: 0003-1488
Publicación seriada: Journal of the American Veterinary Medical Association 
Resumen: Objective: To determine whether low doses of synthetic ACTH could induce a maximal cortisol response in clinically normal dogs and to compare a low-dose ACTH stimulation protocol to a standard high-dose ACTH stimulation protocol in dogs with hyperadrenocorticism. Design: Cohort study. Animals: 6 clinically normal dogs and 7 dogs with hyperadrenocorticism. Procedure: Each clinically normal dog was given 1 of 3 doses of cosyntropin (1, 5, or 10 micrograms/kg [0.45, 2.3, or 4.5 micrograms/lb] of body weight, i.v.) in random order at 2-week intervals. Samples for determination of plasma cortisol and ACTH concentrations were obtained before and 30, 60, 90, and 120 minutes after ACTH administration. Each dog with hyperadrenocorticism was given 2 doses of cosyntropin (5 micrograms/kg or 250 micrograms/dog) in random order at 2-week intervals. In these dogs, samples for determination of plasma cortisol concentrations were obtained before and 60 minutes after ACTH administration. Results: In the clinically normal dogs, peak cortisol concentration and area under the plasma cortisol response curve did not differ significantly among the 3 doses. However, mean plasma cortisol concentration in dogs given 1 microgram/kg peaked at 60 minutes, whereas dogs given doses of 5 or 10 micrograms/kg had peak cortisol values at 90 minutes. In dogs with hyperadrenocorticism, significant differences were not detected between cortisol concentrations after administration of the low or high dose of cosyntropin. Clinical implications: Administration of cosyntropin at a rate of 5 micrograms/kg resulted in maximal stimulation of the adrenal cortex in clinically normal dogs and dogs with hyperadrenocorticism.
URI: http://hdl.handle.net/10553/45840
ISSN: 0003-1488
Fuente: Journal of the American Veterinary Medical Association [ISSN 0003-1488], v. 214 (10), p. 1497-1501
Colección:Artículos
Vista completa

Google ScholarTM

Verifica


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.