Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/42549
Título: Structural and chemical characterization of long-term reverse osmosis membrane fouling in a full scale desalination plant
Autores/as: Melián-Martel, N. 
Sadhwani, J. J. 
Malamis, S.
Ochsenkühn-Petropoulou, M.
Clasificación UNESCO: 330810 Tecnología de aguas residuales
330806 Regeneración del agua
330811 Control de la contaminación del agua
Palabras clave: Reverse osmosis
Membrane fouling
Chemical and structural characterization
Membrane autopsy
Desalination plant
Fecha de publicación: 2012
Publicación seriada: Desalination (Amsterdam) 
Resumen: The assessment of long-term fouling in reverse osmosis (RO) membranes was investigated through extensive membrane autopsy using different analytical techniques. The RO membranes were taken from a seawater desalination plant after 4 years of operation. Chemical and structural characterization was performed using different analytical methods, including visual observation, optical microscopy (OM), scanning electron microscopy with energy dispersive X-ray (SEM-EDX), X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), X-ray fluorescence (XRF), inductively coupled plasma optical emission spectrometry (ICP-OES), atomic absorption spectroscopy (AAS) and ion chromatography (IC). The fouling layer consisted of particulate matter embedded in an apparently amorphous matrix, which was unevenly distributed over the membrane surface with the greatest accumulation in the valley areas. Inorganic and organic foulants were identified in the RO membranes. Inorganic foulants mainly consisted of hydrogen aluminosilicates and halite. The main organics substances identified were proteins, polysaccharides and humic compounds and were attributed to biofouling. Chemical analysis revealed that Si, Al, Cl, Ca, Na, Mg and K were the predominant elements contributing to membrane fouling. The reasons for the deposition of foulants on the RO membranes are the increase of membrane selectivity due to biofouling, the large size of cartridge filters and the high operating pressure.
URI: http://hdl.handle.net/10553/42549
ISSN: 0011-9164
DOI: 10.1016/j.desal.2012.08.011
Fuente: Desalination [ISSN 0011-9164], v. 305, p. 44-53
Colección:Artículos
Vista completa

Citas SCOPUSTM   

72
actualizado el 15-dic-2024

Citas de WEB OF SCIENCETM
Citations

60
actualizado el 15-dic-2024

Visitas

66
actualizado el 03-ago-2024

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.