Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/42549
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Melián-Martel, N. | en_US |
dc.contributor.author | Sadhwani, J. J. | en_US |
dc.contributor.author | Malamis, S. | en_US |
dc.contributor.author | Ochsenkühn-Petropoulou, M. | en_US |
dc.date.accessioned | 2018-11-21T09:59:33Z | - |
dc.date.available | 2018-11-21T09:59:33Z | - |
dc.date.issued | 2012 | en_US |
dc.identifier.issn | 0011-9164 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/42549 | - |
dc.description.abstract | The assessment of long-term fouling in reverse osmosis (RO) membranes was investigated through extensive membrane autopsy using different analytical techniques. The RO membranes were taken from a seawater desalination plant after 4 years of operation. Chemical and structural characterization was performed using different analytical methods, including visual observation, optical microscopy (OM), scanning electron microscopy with energy dispersive X-ray (SEM-EDX), X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), X-ray fluorescence (XRF), inductively coupled plasma optical emission spectrometry (ICP-OES), atomic absorption spectroscopy (AAS) and ion chromatography (IC). The fouling layer consisted of particulate matter embedded in an apparently amorphous matrix, which was unevenly distributed over the membrane surface with the greatest accumulation in the valley areas. Inorganic and organic foulants were identified in the RO membranes. Inorganic foulants mainly consisted of hydrogen aluminosilicates and halite. The main organics substances identified were proteins, polysaccharides and humic compounds and were attributed to biofouling. Chemical analysis revealed that Si, Al, Cl, Ca, Na, Mg and K were the predominant elements contributing to membrane fouling. The reasons for the deposition of foulants on the RO membranes are the increase of membrane selectivity due to biofouling, the large size of cartridge filters and the high operating pressure. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Desalination (Amsterdam) | en_US |
dc.source | Desalination [ISSN 0011-9164], v. 305, p. 44-53 | en_US |
dc.subject | 330810 Tecnología de aguas residuales | en_US |
dc.subject | 330806 Regeneración del agua | en_US |
dc.subject | 330811 Control de la contaminación del agua | en_US |
dc.subject.other | Reverse osmosis | en_US |
dc.subject.other | Membrane fouling | en_US |
dc.subject.other | Chemical and structural characterization | en_US |
dc.subject.other | Membrane autopsy | en_US |
dc.subject.other | Desalination plant | en_US |
dc.title | Structural and chemical characterization of long-term reverse osmosis membrane fouling in a full scale desalination plant | en_US |
dc.type | info:eu-repo/semantics/Article | es |
dc.type | Article | es |
dc.identifier.doi | 10.1016/j.desal.2012.08.011 | |
dc.identifier.scopus | 84866172231 | - |
dc.identifier.isi | 000309898300007 | |
dc.contributor.authorscopusid | 46461751500 | - |
dc.contributor.authorscopusid | 10041008200 | - |
dc.contributor.authorscopusid | 16426025400 | - |
dc.contributor.authorscopusid | 6603813152 | - |
dc.description.lastpage | 53 | - |
dc.description.firstpage | 44 | - |
dc.relation.volume | 305 | - |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Artículo | en_US |
dc.contributor.daisngid | 4015544 | |
dc.contributor.daisngid | 11505361 | |
dc.contributor.daisngid | 667657 | |
dc.contributor.daisngid | 809703 | |
dc.contributor.wosstandard | WOS:Melian-Martel, N | |
dc.contributor.wosstandard | WOS:Sadhwani, JJ | |
dc.contributor.wosstandard | WOS:Malamis, S | |
dc.contributor.wosstandard | WOS:Ochsenkuhn-Petropoulou, M | |
dc.date.coverdate | Noviembre 2012 | |
dc.identifier.ulpgc | Sí | es |
dc.description.sjr | 1,517 | |
dc.description.jcr | 3,041 | |
dc.description.sjrq | Q1 | |
dc.description.jcrq | Q1 | |
dc.description.scie | SCIE | |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.author.dept | GIR Group for the Research on Renewable Energy Systems | - |
crisitem.author.dept | Departamento de Ingeniería de Procesos | - |
crisitem.author.dept | GIR Energía, Corrosión, Residuos y Agua | - |
crisitem.author.dept | Departamento de Ingeniería de Procesos | - |
crisitem.author.orcid | 0000-0001-5271-1443 | - |
crisitem.author.orcid | 0000-0002-6816-2271 | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.parentorg | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.fullName | Melián Martel, Noemí | - |
crisitem.author.fullName | Sadhwani Alonso, José Jaime | - |
Colección: | Artículos |
Citas SCOPUSTM
72
actualizado el 15-dic-2024
Citas de WEB OF SCIENCETM
Citations
60
actualizado el 15-dic-2024
Visitas
66
actualizado el 03-ago-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.