Identificador persistente para citar o vincular este elemento:
https://accedacris.ulpgc.es/jspui/handle/10553/154827
| Título: | Techno-economic modeling and assessment of a binary power plant for the utilization of two-phase geothermal fluids | Autores/as: | Montesdeoca Martínez, Fernando Velázquez Medina, Sergio Leandro Kranz, Stefan |
Clasificación UNESCO: | 3307 Tecnología electrónica | Palabras clave: | Geothermal energy Power plant Binary cycle Thermodynamic modelling Process design, et al. |
Fecha de publicación: | 2026 | Proyectos: | Energías Renovables estratégicas e innovadoras para impulsar la transición hacia la neutralidad climática de la Macaronesia (RESMAC) | Publicación seriada: | Energy Conversion and Management | Resumen: | This paper presents an original design of a binary power plant for the utilization of two-phase geothermal fluids from liquid-dominated fields. The proposed plant concept includes an innovative design aspect based on an additional evaporator for the condensation of previously separated geothermal steam. The model of the proposed system is implemented, and a parametric study conducted through simulations to measure the effect of different process and component design variables on thermodynamic performance. Three dry organic fluids, n-pentane, isopentane, and n-butane, were selected for the thermodynamic analysis. A comparative study was also undertaken to determine whether the proposed system could improve upon the specific power output and economic performance of a single-flash system and a flash-binary system under the same geothermal resource conditions. A maximum net power output of 13.59 MW was achieved using n-pentane as the working fluid for a turbine inlet temperature of 175 ◦C, a wellhead pressure of 13 bar, and an approach temperature difference in the dry cooler of 16 K. The results of the comparative study showed that the proposed system offers both thermodynamic and techno-economic benefits over other geothermal energy systems. Although capital expenditure for the proposed design is 5.6% higher than that for the single-flash system, a more than doubled specific power output ensures a better economic performance. Additionally, the proposed design shows a specific power output improvement of up to 25.6% compared to the flash-binary system while capital expenditure is 19.2% lower. | URI: | https://accedacris.ulpgc.es/jspui/handle/10553/154827 | ISSN: | 0196-8904 | DOI: | 10.1016/j.enconman.2026.121050 | Fuente: | Energy Conversion and Management [ISSN 0196-8904], v.351 (Enero 2026) |
| Colección: | Artículos |
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.