Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/76877
Campo DC Valoridioma
dc.contributor.authorLópez Silva, S. M.en_US
dc.contributor.authorSilveira, J. P.en_US
dc.contributor.authorHerrera, L.en_US
dc.contributor.authorDotor, M. L.en_US
dc.contributor.authorGiannetti, R.en_US
dc.date.accessioned2020-12-21T09:25:37Z-
dc.date.available2020-12-21T09:25:37Z-
dc.date.issued2005en_US
dc.identifier.issn0030-3917en_US
dc.identifier.otherWoS-
dc.identifier.urihttp://hdl.handle.net/10553/76877-
dc.description.abstractPhotoplethysmography is a technique based on optical principles, which is widely used in the medical practice for peripheral monitoring of the cardiac frequency. Here we expose the results obtained by transmittance photoplethysmography in pig intra-peritoneal organs along a surgical intervention, using a measurement system based on two near infrared laser diodes. The analysis of the signals recorded at 750 nm and 850 nm in aorta, gastric wall, mesentery and mesocolon, has shown the affordability to perform photoplethysmography and pulse oximetry for visceral perfusion evaluation.en_US
dc.description.abstractLa fotopletismografía es una técnica basada en principios ópticos ampliamente utilizada en clínica para la monitorización periférica de la frecuencia cardiaca. Hemos realizado un estudio preliminar de fotopletismografía por transmisión en órganos intra-abdominales de un cerdo durante una intervención quirúrgica con un sistema basado en dos diodos láser. El análisis de los fotopletismogramas registrados a 750 nm y 850 nm en la aorta, pared gástrica, raíz del mesenterio y el mesocolon demuestra la viabilidad de la fotopletismografía y la oximetría de pulso para la evaluación objetiva de la perfusión visceral "in situ". Palabras clave: diodos láser, fotopletismografía, oximetría de pulsoen_US
dc.languagespaen_US
dc.relation.ispartofOptica Pura y Aplicadaen_US
dc.sourceÓptica Pura y Aplicada [ISSN 0030-3917], v. 38 (1), p. 23-30, (Marzo 2005)en_US
dc.subject3307 Tecnología electrónicaen_US
dc.subject3325 Tecnología de las telecomunicacionesen_US
dc.subject.otherLaser Diodesen_US
dc.subject.otherPhotoplethysmographyen_US
dc.subject.otherPulse Oximetryen_US
dc.subject.otherDiodos láseren_US
dc.subject.otherOximetría de pulsoen_US
dc.subject.otherFotopletismografíaen_US
dc.titleUtilidad de la fotopletismografía por transmisión con diodos láser infrarrojos en el estudio de la perfusión visceral: estudio preliminaren_US
dc.title.alternativeUtility of transmittance photoplethysmography with near infrared laser diodes for the study of visceral perfusion: preliminary studyen_US
dc.typeinfo:eu-repo/semantics/Articleen_US
dc.typeArticleen_US
dc.identifier.isi000420785500010-
dc.identifier.eissn2171-8814-
dc.description.lastpage30en_US
dc.identifier.issue1-
dc.description.firstpage23en_US
dc.relation.volume38en_US
dc.investigacionIngeniería y Arquitecturaen_US
dc.type2Artículoen_US
dc.contributor.daisngid3913733-
dc.contributor.daisngid3469245-
dc.contributor.daisngid8621274-
dc.contributor.daisngid765840-
dc.contributor.daisngid641974-
dc.description.numberofpages8en_US
dc.utils.revisionen_US
dc.contributor.wosstandardWOS:Silva, SML-
dc.contributor.wosstandardWOS:Silveira, JP-
dc.contributor.wosstandardWOS:Herrera, L-
dc.contributor.wosstandardWOS:Dotor, ML-
dc.contributor.wosstandardWOS:Giannetti, R-
dc.date.coverdateMarzo 2005en_US
dc.identifier.ulpgcen_US
dc.description.esciESCI
item.fulltextCon texto completo-
item.grantfulltextopen-
Colección:Artículos
miniatura
pdf
Adobe PDF (843,8 kB)
Vista resumida

Citas de WEB OF SCIENCETM
Citations

2
actualizado el 25-feb-2024

Visitas

79
actualizado el 30-dic-2023

Descargas

18
actualizado el 30-dic-2023

Google ScholarTM

Verifica


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.