Please use this identifier to cite or link to this item: http://hdl.handle.net/10553/76877
DC FieldValueLanguage
dc.contributor.authorLópez Silva, S. M.en_US
dc.contributor.authorSilveira, J. P.en_US
dc.contributor.authorHerrera, L.en_US
dc.contributor.authorDotor, M. L.en_US
dc.contributor.authorGiannetti, R.en_US
dc.date.accessioned2020-12-21T09:25:37Z-
dc.date.available2020-12-21T09:25:37Z-
dc.date.issued2005en_US
dc.identifier.issn0030-3917en_US
dc.identifier.otherWoS-
dc.identifier.urihttp://hdl.handle.net/10553/76877-
dc.description.abstractPhotoplethysmography is a technique based on optical principles, which is widely used in the medical practice for peripheral monitoring of the cardiac frequency. Here we expose the results obtained by transmittance photoplethysmography in pig intra-peritoneal organs along a surgical intervention, using a measurement system based on two near infrared laser diodes. The analysis of the signals recorded at 750 nm and 850 nm in aorta, gastric wall, mesentery and mesocolon, has shown the affordability to perform photoplethysmography and pulse oximetry for visceral perfusion evaluation.en_US
dc.description.abstractLa fotopletismografía es una técnica basada en principios ópticos ampliamente utilizada en clínica para la monitorización periférica de la frecuencia cardiaca. Hemos realizado un estudio preliminar de fotopletismografía por transmisión en órganos intra-abdominales de un cerdo durante una intervención quirúrgica con un sistema basado en dos diodos láser. El análisis de los fotopletismogramas registrados a 750 nm y 850 nm en la aorta, pared gástrica, raíz del mesenterio y el mesocolon demuestra la viabilidad de la fotopletismografía y la oximetría de pulso para la evaluación objetiva de la perfusión visceral "in situ". Palabras clave: diodos láser, fotopletismografía, oximetría de pulsoen_US
dc.languagespaen_US
dc.relation.ispartofOptica Pura y Aplicadaen_US
dc.sourceÓptica Pura y Aplicada [ISSN 0030-3917], v. 38 (1), p. 23-30, (Marzo 2005)en_US
dc.subject3307 Tecnología electrónicaen_US
dc.subject3325 Tecnología de las telecomunicacionesen_US
dc.subject.otherLaser Diodesen_US
dc.subject.otherPhotoplethysmographyen_US
dc.subject.otherPulse Oximetryen_US
dc.subject.otherDiodos láseren_US
dc.subject.otherOximetría de pulsoen_US
dc.subject.otherFotopletismografíaen_US
dc.titleUtilidad de la fotopletismografía por transmisión con diodos láser infrarrojos en el estudio de la perfusión visceral: estudio preliminaren_US
dc.title.alternativeUtility of transmittance photoplethysmography with near infrared laser diodes for the study of visceral perfusion: preliminary studyen_US
dc.typeinfo:eu-repo/semantics/Articleen_US
dc.typeArticleen_US
dc.identifier.isi000420785500010-
dc.identifier.eissn2171-8814-
dc.description.lastpage30en_US
dc.identifier.issue1-
dc.description.firstpage23en_US
dc.relation.volume38en_US
dc.investigacionIngeniería y Arquitecturaen_US
dc.type2Artículoen_US
dc.contributor.daisngid3913733-
dc.contributor.daisngid3469245-
dc.contributor.daisngid8621274-
dc.contributor.daisngid765840-
dc.contributor.daisngid641974-
dc.description.numberofpages8en_US
dc.utils.revisionen_US
dc.contributor.wosstandardWOS:Silva, SML-
dc.contributor.wosstandardWOS:Silveira, JP-
dc.contributor.wosstandardWOS:Herrera, L-
dc.contributor.wosstandardWOS:Dotor, ML-
dc.contributor.wosstandardWOS:Giannetti, R-
dc.date.coverdateMarzo 2005en_US
dc.identifier.ulpgcen_US
dc.description.esciESCI
item.fulltextCon texto completo-
item.grantfulltextopen-
Appears in Collections:Artículos
Thumbnail
pdf
Adobe PDF (843,8 kB)
Show simple item record

WEB OF SCIENCETM
Citations

2
checked on Feb 25, 2024

Page view(s)

79
checked on Dec 30, 2023

Download(s)

18
checked on Dec 30, 2023

Google ScholarTM

Check


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.