Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/74272
DC Field | Value | Language |
---|---|---|
dc.contributor.author | López Silva, Sonnia María | en_US |
dc.contributor.author | Dotor Castilla, María Luísa | en_US |
dc.contributor.author | Silveira Martín, Juan Pedro | en_US |
dc.date.accessioned | 2020-09-06T12:44:31Z | - |
dc.date.available | 2020-09-06T12:44:31Z | - |
dc.date.issued | 2003 | en_US |
dc.identifier.issn | 1083-3668 | en_US |
dc.identifier.other | WoS | - |
dc.identifier.uri | http://hdl.handle.net/10553/74272 | - |
dc.description.abstract | Pulse oximeters are widely used for noninvasive monitoring of oxygen saturation in arterial blood hemoglobin. We present a transmittance pulse oximetry system based on near-infrared (NIR) laser diodes (750 and 850 nm) for monitoring oxygen saturation of arterial blood hemoglobin. The pulse oximetry system is made up of the optical sensor, sensor electronics, and processing block. Also, we show experimental results obtained during the development of the whole NIR transmittance pulse oximetry system along with modifications in the sensor configuration, signal processing algorithm, and calibration procedure. issues concerning wavelength selection and its implications for the improvement of the transmittance pulse oximetry technique are discussed. The results obtained demonstrate the proposed system's usefulness in monitoring a wide range of oxygen saturation levels. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Journal of Biomedical Optics | en_US |
dc.source | Journal of Biomedical Optics [ISSN 1083-3668], v. 8 (3), p. 525-533, (Julio 2003) | en_US |
dc.subject | 3311 tecnología de la instrumentación | en_US |
dc.subject.other | Oximetry | en_US |
dc.subject.other | Sensors | en_US |
dc.subject.other | Semiconductor lasers | en_US |
dc.subject.other | Oxygen | en_US |
dc.subject.other | Rhodamine B | en_US |
dc.subject.other | Oximeters | en_US |
dc.subject.other | Linear filtering | en_US |
dc.subject.other | Transmittance | en_US |
dc.subject.other | Signal processing | en_US |
dc.subject.other | Blood | en_US |
dc.title | Near-infrared transmittance pulse oximetry with laser diodes | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1117/1.1578495 | en_US |
dc.identifier.scopus | 1542679021 | - |
dc.identifier.isi | 000184606400026 | - |
dc.contributor.authorscopusid | 6603011574 | - |
dc.contributor.authorscopusid | 7006629739 | - |
dc.contributor.authorscopusid | 56137466300 | - |
dc.identifier.eissn | 1560-2281 | - |
dc.description.lastpage | 533 | en_US |
dc.identifier.issue | 3 | - |
dc.description.firstpage | 525 | en_US |
dc.relation.volume | 8 | en_US |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Artículo | en_US |
dc.contributor.daisngid | 3913733 | - |
dc.contributor.daisngid | 7131804 | - |
dc.contributor.daisngid | 10784874 | - |
dc.description.numberofpages | 9 | en_US |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:Silva, SML | - |
dc.contributor.wosstandard | WOS:Castilla, MLD | - |
dc.contributor.wosstandard | WOS:Martin, JPS | - |
dc.date.coverdate | Julio 2003 | en_US |
dc.identifier.ulpgc | Sí | es |
dc.description.jcr | 3,541 | |
dc.description.jcrq | Q1 | |
dc.description.scie | SCIE | |
item.grantfulltext | open | - |
item.fulltext | Con texto completo | - |
crisitem.author.fullName | López Silva, Sonnia María | - |
Appears in Collections: | Artículos |
SCOPUSTM
Citations
30
checked on Nov 17, 2024
WEB OF SCIENCETM
Citations
28
checked on Nov 17, 2024
Page view(s)
89
checked on May 4, 2024
Download(s)
315
checked on May 4, 2024
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.