Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/74272
Título: | Near-infrared transmittance pulse oximetry with laser diodes | Autores/as: | López Silva, Sonnia María Dotor Castilla, María Luísa Silveira Martín, Juan Pedro |
Clasificación UNESCO: | 3311 tecnología de la instrumentación | Palabras clave: | Oximetry Sensors Semiconductor lasers Oxygen Rhodamine B, et al. |
Fecha de publicación: | 2003 | Publicación seriada: | Journal of Biomedical Optics | Resumen: | Pulse oximeters are widely used for noninvasive monitoring of oxygen saturation in arterial blood hemoglobin. We present a transmittance pulse oximetry system based on near-infrared (NIR) laser diodes (750 and 850 nm) for monitoring oxygen saturation of arterial blood hemoglobin. The pulse oximetry system is made up of the optical sensor, sensor electronics, and processing block. Also, we show experimental results obtained during the development of the whole NIR transmittance pulse oximetry system along with modifications in the sensor configuration, signal processing algorithm, and calibration procedure. issues concerning wavelength selection and its implications for the improvement of the transmittance pulse oximetry technique are discussed. The results obtained demonstrate the proposed system's usefulness in monitoring a wide range of oxygen saturation levels. | URI: | http://hdl.handle.net/10553/74272 | ISSN: | 1083-3668 | DOI: | 10.1117/1.1578495 | Fuente: | Journal of Biomedical Optics [ISSN 1083-3668], v. 8 (3), p. 525-533, (Julio 2003) |
Colección: | Artículos |
Citas SCOPUSTM
30
actualizado el 17-nov-2024
Citas de WEB OF SCIENCETM
Citations
28
actualizado el 17-nov-2024
Visitas
89
actualizado el 04-may-2024
Descargas
315
actualizado el 04-may-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.