Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/70142
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Ramos Macias, Angel | en_US |
dc.contributor.author | Ramos De Miguel, Ángel | en_US |
dc.contributor.author | Rodriguez Montesdeoca,Isaura | en_US |
dc.contributor.author | Borkoski Barreiro, Silvia | en_US |
dc.contributor.author | Falcón González, Juan Carlos | en_US |
dc.date.accessioned | 2020-02-05T12:52:39Z | - |
dc.date.available | 2020-02-05T12:52:39Z | - |
dc.date.issued | 2019 | en_US |
dc.identifier.issn | 1420-3030 | en_US |
dc.identifier.other | Scopus | - |
dc.identifier.uri | http://hdl.handle.net/10553/70142 | - |
dc.description.abstract | Introduction: Bilateral vestibulopathy is an important cause of imbalance that is misdiagnosed. The clinical management of patients with bilateral vestibular loss remains difficult as there is no clear evidence for an effective treatment. In this paper, we try to analyze the effect of chronic electrical stimulation and adaptation to electrical stimulation of the vestibular system in humans when stimulating the otolith organ with a constant pulse train to mitigate imbalance due to bilateral vestibular dysfunction (BVD). Methods: We included 2 patients in our study with BVD according to Criteria Consensus of the Classification Committee of the Bárány Society. Both cases were implanted by using a full-band straight electrode to stimulate the otoliths organs and simultaneously for the cochlear stimulation we use a perimodiolar electrode. Results: In both cases Vestibular and clinical test (video head impulse test, videonistagmography cervical vestibular evoked myogenic potentials, cVEMP and oVEMP), subjective visual vertical test, computerized dynamic posturography, dynamic gait index, Time UP and Go test and dizziness handicap index) were performed. Posture and gait metrics reveal important improvement if compare with preoperartive situation. Oscillopsia, unsteadiness, independence and quality of life improved to almost normal situation. Discussion/Conclusion: Prosthetic implantation of the otolith organ in humans is technically feasible. Electrical stimulation might have potential effects on balance and this is stable after 1 year follow-up. This research provides new possibilities for the development of vestibular implants to improve gravito-inertial acceleration sensation, in this case by the otoliths stimulation. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Audiology and Neuro-Otology | en_US |
dc.source | Audiology and Neurotology [ISSN 1420-3030] | en_US |
dc.subject | 32 Ciencias médicas | en_US |
dc.subject.other | Balance | en_US |
dc.subject.other | Bilateral vestibulopathy | en_US |
dc.subject.other | Saccule | en_US |
dc.subject.other | Utricle | en_US |
dc.subject.other | Vestibular implant | en_US |
dc.title | Chronic Electrical Stimulation of the Otolith Organ: Preliminary Results in Humans with Bilateral Vestibulopathy and Sensorineural Hearing Loss | en_US |
dc.type | info:eu-repo/semantics/article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1159/000503600 | en_US |
dc.identifier.scopus | 85076317707 | - |
dc.contributor.authorscopusid | 6701550535 | - |
dc.contributor.authorscopusid | 56848284600 | - |
dc.contributor.authorscopusid | 57212250099 | - |
dc.contributor.authorscopusid | 55371597700 | - |
dc.contributor.authorscopusid | 36618690700 | - |
dc.investigacion | Ciencias de la Salud | en_US |
dc.type2 | Artículo | en_US |
dc.utils.revision | Sí | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.description.sjr | 1,132 | |
dc.description.jcr | 1,549 | |
dc.description.sjrq | Q1 | |
dc.description.jcrq | Q3 | |
dc.description.scie | SCIE | |
item.fulltext | Sin texto completo | - |
item.grantfulltext | none | - |
crisitem.author.dept | GIR SIANI: Ingeniería biomédica aplicada a estimulación neural y sensorial | - |
crisitem.author.dept | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.dept | Departamento de Ciencias Médicas y Quirúrgicas | - |
crisitem.author.dept | GIR SIANI: Modelización y Simulación Computacional | - |
crisitem.author.dept | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.dept | Departamento de Informática y Sistemas | - |
crisitem.author.dept | GIR SIANI: Ingeniería biomédica aplicada a estimulación neural y sensorial | - |
crisitem.author.dept | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.dept | GIR SIANI: Ingeniería biomédica aplicada a estimulación neural y sensorial | - |
crisitem.author.dept | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.dept | GIR SIANI: Ingeniería biomédica aplicada a estimulación neural y sensorial | - |
crisitem.author.dept | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.orcid | 0000-0002-4709-5559 | - |
crisitem.author.orcid | 0000-0002-0528-815X | - |
crisitem.author.orcid | 0000-0002-5743-4374 | - |
crisitem.author.parentorg | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.parentorg | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.parentorg | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.parentorg | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.parentorg | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.fullName | Ramos Macías, Ángel Manuel | - |
crisitem.author.fullName | Ramos De Miguel, Ángel | - |
crisitem.author.fullName | Rodriguez Montesdeoca,Isaura | - |
crisitem.author.fullName | Borkoski Barreiro,Silvia | - |
crisitem.author.fullName | Falcon Gonzalez,Juan Carlos | - |
Colección: | Artículos |
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.