Please use this identifier to cite or link to this item: http://hdl.handle.net/10553/53990
Title: Application of microwave-assisted extraction and ultra-high performance liquid chromatography-tandem mass spectrometry for the analysis of sex hormones and corticosteroids in sewage sludge samples
Authors: Guedes-Alonso, Rayco 
Santana-Viera, Sergio 
Montesdeoca-Esponda, Sarah 
Afonso-Olivares, Cristina 
Sosa-Ferrera, Zoraida 
Santana-Rodríguez, José Juan 
UNESCO Clasification: 2302 Bioquímica
2391 Química ambiental
Keywords: Mass spectrometry
Microwave-assisted extraction
Sludge
Steroid hormones
Ultra-high performance liquid chromatography
Issue Date: 2016
Publisher: 1618-2642
Project: Estrategias Para El Control y Remediación Natural de Compuestos Orgánicos Emergentes en Aguas Residuales. Impacto en El Medio Marino. 
Journal: Analytical and Bioanalytical Chemistry 
Abstract: Hormonal compounds are a concern to the international community because they can affect the aquatic biota and are therefore considered to be endocrine-disrupting compounds. These compounds have lipophilic properties, so they tend to accumulate in solid matrices, such as sewage sludge. This work presents the optimization of a microwave-assisted extraction process combined with ultra-high performance liquid chromatography–tandem mass spectrometry for the determination of 15 hormonal compounds in sludge samples. The proposed method has relative standard deviations below 23 %, good recoveries (over 71 %) for all compounds, detection limits that ranged from 1.1 to 7.9 ng g−1 and quantification limits which ranged from 3.7 to 26.3 ng g−1. The method was used to analyse sludge samples from four different wastewater treatment plants of Gran Canaria (Spain) with different wastewater treatments. 17β-estradiol, 17α-ethynylestradiol, norgestrel and cortisone were detected in sludge samples at concentrations that ranged from 17.3 to 1.44 × 103 ng g−1. The developed method permits the use of small quantities of sample and organic solvents, presents short extractions times and is the first one based on microwave-assisted extraction for the analysis of both sex hormones and corticosteroids.
URI: http://hdl.handle.net/10553/53990
ISSN: 1618-2642
DOI: 10.1007/s00216-016-9810-7
Source: Analytical and Bioanalytical Chemistry [ISSN 1618-2642], Septiembre 2016, v. 408 (24), p. 6833-6844
Appears in Collections:Artículos
Adobe PDF (1,34 MB)
Show full item record

SCOPUSTM   
Citations

20
checked on Apr 14, 2024

WEB OF SCIENCETM
Citations

18
checked on Feb 25, 2024

Page view(s)

125
checked on Mar 9, 2024

Download(s)

2
checked on Mar 9, 2024

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.