Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/50920
Título: Assessment of cardiac output with transpulmonary thermodilution during exercise in humans
Autores/as: Calbet, Jose A. L. 
Boushel, Robert
Clasificación UNESCO: 241106 Fisiología del ejercicio
Palabras clave: cardiac output
indocyanine
exercise
thermodilution
human
Fecha de publicación: 2015
Editor/a: 8750-7587
Publicación seriada: Journal of Applied Physiology 
Resumen: The accuracy and reproducibility of transpulmonary thermodilution (TPTd) to assess cardiac output (Q˙ ) in exercising men was determined using indocyanine green (ICG) dilution as a reference method. TPTd has been utilized for the assessment of Q˙ and preload indexes of global end-diastolic volume and intrathoracic blood volume, as well as extravascular lung water (EVLW) in resting humans. It remains unknown if this technique is also accurate and reproducible during exercise. Sixteen healthy men underwent catheterization of the right femoral vein (for iced saline injection), an antecubital vein (ICG injection), and femoral artery (thermistor) to determine their Q˙ by TPTd and ICG concentration during incremental one- and two-legged pedaling on a cycle ergometer and combined arm cranking with leg pedaling to exhaustion. There was a close relationship between TPTd-Q˙ and ICG-Q˙ (r 0.95, n 151, standard error of the estimate: 1.452 l/min, P 0.001; mean difference of 0.06 l/min; limits of agreement 2.98 to 2.86 l/min), and TPTd-Q˙ and ICG-Q˙ increased linearly with oxygen uptake with similar intercepts and slopes. Both methods had mean coefficients of variation close to 5% for Q˙ , global end-diastolic volume, and intrathoracic blood volume. The mean coefficient of variation of EVLW, assessed with both indicators (ICG and thermal) was 17% and was sensitive enough to detect a reduction in EVLW of 107 ml when changing from resting supine to upright exercise. In summary, TPTd with bolus injection into the femoral vein is an accurate and reproducible method to assess Q˙ during exercise in humans.
URI: http://hdl.handle.net/10553/50920
ISSN: 8750-7587
DOI: 10.1152/japplphysiol.00686.2014
Fuente: Journal Of Applied Physiology[ISSN 8750-7587],v. 118 (1), p. 1-10
Colección:Artículos
Vista completa

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.