Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/50268
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Rodríguez de Castro, Felipe Carlos B. | en_US |
dc.contributor.author | Rey, A. | en_US |
dc.contributor.author | Caminero, J. | en_US |
dc.contributor.author | Cabrera Navarro, Pedro | en_US |
dc.contributor.author | Facal, P. | en_US |
dc.contributor.author | Carrillo Díaz, Teresa | en_US |
dc.contributor.author | López, Luis | en_US |
dc.date.accessioned | 2018-11-24T14:43:04Z | - |
dc.date.available | 2018-11-24T14:43:04Z | - |
dc.date.issued | 1995 | en_US |
dc.identifier.issn | 0956-5507 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/50268 | - |
dc.description.abstract | We review our experience of transbronchial fine needle aspiration (TBFNA) over a 3-year period. A total of 112 TBFNAs were performed on 95 patients. Four aspirates were from peripheral lung lesions, 20 from non-ulcerated submucosal infiltrative lesions, 19 from mediastinal abnormalities close to the tracheobronchial tree, and the remaining 69 were for staging of bronchogenic carcinoma with apparent mediastinal lymph node spread, evaluated by chest computed tomography (CT). In the 20 submucosal lesions TBFNA reached a sensitivity of 82.3%, providing the only evidence of a malignant process in five cases. With respect to the 19 mediastinal lesions arising in close proximity to the central airways, TBFNA permitted a diagnosis in cases that would otherwise have required more invasive procedures, although the diagnostic sensitivity of the technique in this group of patients was poor (26%). In the mediastinal staging group, the sensitivity was 76.9%, with no false positive results. Complete sensitivity of TBFNA for the detection of disease was 65.8%. We conclude that TBFNA is a reliable and low risk procedure. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Cytopathology | en_US |
dc.source | Cytopathology [ISSN 0956-5507], v. 6, p. 22-29 | en_US |
dc.subject | 32 Ciencias médicas | en_US |
dc.subject | 3207 Patología | en_US |
dc.subject.other | Bronchogenic-Carcinoma | en_US |
dc.subject.other | Diagnosis | en_US |
dc.title | Transbronchial fine needle aspiration in clinical practice | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1111/j.1365-2303.1995.tb00004.x | en_US |
dc.identifier.pmid | 7734698 | - |
dc.identifier.scopus | 0028945604 | - |
dc.identifier.isi | A1995QG87900004 | - |
dc.contributor.orcid | #NODATA# | - |
dc.contributor.orcid | #NODATA# | - |
dc.contributor.orcid | #NODATA# | - |
dc.contributor.orcid | #NODATA# | - |
dc.contributor.orcid | #NODATA# | - |
dc.contributor.orcid | #NODATA# | - |
dc.contributor.orcid | #NODATA# | - |
dc.contributor.authorscopusid | 57206131705 | - |
dc.contributor.authorscopusid | 57206131705 | - |
dc.contributor.authorscopusid | 7202860969 | - |
dc.contributor.authorscopusid | 57188992735 | - |
dc.contributor.authorscopusid | 7003423561 | - |
dc.contributor.authorscopusid | 56817239200 | - |
dc.contributor.authorscopusid | 56817239200 | - |
dc.contributor.authorscopusid | 6602697711 | - |
dc.contributor.authorscopusid | 7003526269 | - |
dc.description.lastpage | 29 | en_US |
dc.identifier.issue | 1 | - |
dc.description.firstpage | 22 | en_US |
dc.relation.volume | 6 | en_US |
dc.investigacion | Ciencias de la Salud | en_US |
dc.type2 | Artículo | en_US |
dc.contributor.daisngid | 30484275 | - |
dc.contributor.daisngid | 5872526 | - |
dc.contributor.daisngid | 8054193 | - |
dc.contributor.daisngid | 662982 | - |
dc.contributor.daisngid | 22916976 | - |
dc.contributor.daisngid | 2546479 | - |
dc.contributor.daisngid | 5529606 | - |
dc.description.numberofpages | 8 | en_US |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:DECASTRO, FR | - |
dc.contributor.wosstandard | WOS:REY, A | - |
dc.contributor.wosstandard | WOS:CAMINERO, J | - |
dc.contributor.wosstandard | WOS:CABRERA, P | - |
dc.contributor.wosstandard | WOS:FACAL, P | - |
dc.contributor.wosstandard | WOS:CARRILLO, T | - |
dc.date.coverdate | Enero 1995 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-MED | en_US |
dc.description.scie | SCIE | - |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.author.dept | GIR IUIBS: Patología y Tecnología médica | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | Departamento de Ciencias Médicas y Quirúrgicas | - |
crisitem.author.dept | GIR IUIBS: Patología y Tecnología médica | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | Departamento de Ciencias Médicas y Quirúrgicas | - |
crisitem.author.orcid | 0000-0002-6812-2739 | - |
crisitem.author.orcid | 0000-0002-3047-8908 | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.fullName | Rodríguez De Castro, Felipe Carlos B. | - |
crisitem.author.fullName | Carrillo Díaz, Teresa | - |
Colección: | Artículos |
Citas SCOPUSTM
23
actualizado el 24-nov-2024
Citas de WEB OF SCIENCETM
Citations
13
actualizado el 06-mar-2022
Visitas
49
actualizado el 02-mar-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.