Please use this identifier to cite or link to this item: http://hdl.handle.net/10553/50268
DC FieldValueLanguage
dc.contributor.authorRodríguez de Castro, Felipe Carlos B.en_US
dc.contributor.authorRey, A.en_US
dc.contributor.authorCaminero, J.en_US
dc.contributor.authorCabrera Navarro, Pedroen_US
dc.contributor.authorFacal, P.en_US
dc.contributor.authorCarrillo Díaz, Teresaen_US
dc.contributor.authorLópez, Luisen_US
dc.date.accessioned2018-11-24T14:43:04Z-
dc.date.available2018-11-24T14:43:04Z-
dc.date.issued1995en_US
dc.identifier.issn0956-5507en_US
dc.identifier.urihttp://hdl.handle.net/10553/50268-
dc.description.abstractWe review our experience of transbronchial fine needle aspiration (TBFNA) over a 3-year period. A total of 112 TBFNAs were performed on 95 patients. Four aspirates were from peripheral lung lesions, 20 from non-ulcerated submucosal infiltrative lesions, 19 from mediastinal abnormalities close to the tracheobronchial tree, and the remaining 69 were for staging of bronchogenic carcinoma with apparent mediastinal lymph node spread, evaluated by chest computed tomography (CT). In the 20 submucosal lesions TBFNA reached a sensitivity of 82.3%, providing the only evidence of a malignant process in five cases. With respect to the 19 mediastinal lesions arising in close proximity to the central airways, TBFNA permitted a diagnosis in cases that would otherwise have required more invasive procedures, although the diagnostic sensitivity of the technique in this group of patients was poor (26%). In the mediastinal staging group, the sensitivity was 76.9%, with no false positive results. Complete sensitivity of TBFNA for the detection of disease was 65.8%. We conclude that TBFNA is a reliable and low risk procedure.en_US
dc.languageengen_US
dc.relation.ispartofCytopathologyen_US
dc.sourceCytopathology [ISSN 0956-5507], v. 6, p. 22-29en_US
dc.subject32 Ciencias médicasen_US
dc.subject3207 Patologíaen_US
dc.subject.otherBronchogenic-Carcinomaen_US
dc.subject.otherDiagnosisen_US
dc.titleTransbronchial fine needle aspiration in clinical practiceen_US
dc.typeinfo:eu-repo/semantics/Articleen_US
dc.typeArticleen_US
dc.identifier.doi10.1111/j.1365-2303.1995.tb00004.xen_US
dc.identifier.pmid7734698-
dc.identifier.scopus0028945604-
dc.identifier.isiA1995QG87900004-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.authorscopusid57206131705-
dc.contributor.authorscopusid57206131705-
dc.contributor.authorscopusid7202860969-
dc.contributor.authorscopusid57188992735-
dc.contributor.authorscopusid7003423561-
dc.contributor.authorscopusid56817239200-
dc.contributor.authorscopusid56817239200-
dc.contributor.authorscopusid6602697711-
dc.contributor.authorscopusid7003526269-
dc.description.lastpage29en_US
dc.identifier.issue1-
dc.description.firstpage22en_US
dc.relation.volume6en_US
dc.investigacionCiencias de la Saluden_US
dc.type2Artículoen_US
dc.contributor.daisngid30484275-
dc.contributor.daisngid5872526-
dc.contributor.daisngid8054193-
dc.contributor.daisngid662982-
dc.contributor.daisngid22916976-
dc.contributor.daisngid2546479-
dc.contributor.daisngid5529606-
dc.description.numberofpages8en_US
dc.utils.revisionen_US
dc.contributor.wosstandardWOS:DECASTRO, FR-
dc.contributor.wosstandardWOS:REY, A-
dc.contributor.wosstandardWOS:CAMINERO, J-
dc.contributor.wosstandardWOS:CABRERA, P-
dc.contributor.wosstandardWOS:FACAL, P-
dc.contributor.wosstandardWOS:CARRILLO, T-
dc.date.coverdateEnero 1995en_US
dc.identifier.ulpgcen_US
dc.contributor.buulpgcBU-MEDen_US
dc.description.scieSCIE-
item.grantfulltextnone-
item.fulltextSin texto completo-
crisitem.author.deptGIR IUIBS: Patología y Tecnología médica-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Ciencias Médicas y Quirúrgicas-
crisitem.author.deptGIR IUIBS: Patología y Tecnología médica-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Ciencias Médicas y Quirúrgicas-
crisitem.author.orcid0000-0002-6812-2739-
crisitem.author.orcid0000-0002-3047-8908-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.fullNameRodríguez De Castro, Felipe Carlos B.-
crisitem.author.fullNameCarrillo Díaz, Teresa-
Appears in Collections:Artículos
Show simple item record

SCOPUSTM   
Citations

23
checked on Nov 17, 2024

WEB OF SCIENCETM
Citations

13
checked on Mar 6, 2022

Page view(s)

49
checked on Mar 2, 2024

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.