Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/46152
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Morales, Aythami | en_US |
dc.contributor.author | González, Ester | en_US |
dc.contributor.author | Ferrer, Miguel A. | en_US |
dc.contributor.other | Gonzalez-Sosa, Ester | - |
dc.contributor.other | Ferrer, Miguel A | - |
dc.contributor.other | Morales, Aythami | - |
dc.date.accessioned | 2018-11-23T01:50:55Z | - |
dc.date.available | 2018-11-23T01:50:55Z | - |
dc.date.issued | 2012 | en_US |
dc.identifier.issn | 1424-8220 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/46152 | - |
dc.description.abstract | Personal recognition through hand-based biometrics has attracted the interest of many researchers in the last twenty years. A significant number of proposals based on different procedures and acquisition devices have been published in the literature. However, comparisons between devices and their interoperability have not been thoroughly studied. This paper tries to fill this gap by proposing procedures to improve the interoperability among different hand biometric schemes. The experiments were conducted on a database made up of 8,320 hand images acquired from six different hand biometric schemes, including a flat scanner, webcams at different wavelengths, high quality cameras, and contactless devices. Acquisitions on both sides of the hand were included. Our experiment includes four feature extraction methods which determine the best performance among the different scenarios for two of the most popular hand biometrics: hand shape and palm print. We propose smoothing techniques at the image and feature levels to reduce interdevice variability. Results suggest that comparative hand shape offers better performance in terms of interoperability than palm prints, but palm prints can be more effective when using similar sensors. | en_US |
dc.language | eng | en_US |
dc.publisher | 1424-8220 | |
dc.relation.ispartof | Sensors | en_US |
dc.source | Sensors[ISSN 1424-8220], v. 12, p. 1352-1382 | en_US |
dc.subject | 3307 Tecnología electrónica | en_US |
dc.subject.other | biometric identification | en_US |
dc.subject.other | hand based biometrics | en_US |
dc.subject.other | hand geometry | en_US |
dc.subject.other | interoperability | en_US |
dc.subject.other | palm texture | en_US |
dc.title | On the feasibility of interoperable schemes in hand biometrics | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.3390/s120201352 | en_US |
dc.identifier.scopus | 84857611655 | - |
dc.identifier.isi | 000300720300012 | - |
dcterms.isPartOf | Sensors | |
dcterms.source | Sensors[ISSN 1424-8220],v. 12 (2), p. 1352-1382 | |
dc.contributor.authorscopusid | 24476050500 | - |
dc.contributor.authorscopusid | 57199756127 | - |
dc.contributor.authorscopusid | 55636321172 | - |
dc.description.lastpage | 1382 | en_US |
dc.description.firstpage | 1352 | en_US |
dc.relation.volume | 12 | en_US |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Artículo | en_US |
dc.identifier.wos | WOS:000300720300012 | - |
dc.contributor.daisngid | 1418808 | - |
dc.contributor.daisngid | 3150887 | - |
dc.contributor.daisngid | 233119 | - |
dc.identifier.investigatorRID | L-3544-2013 | - |
dc.identifier.investigatorRID | L-3863-2013 | - |
dc.identifier.investigatorRID | L-2529-2013 | - |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:Morales, A | - |
dc.contributor.wosstandard | WOS:Gonzalez, E | - |
dc.contributor.wosstandard | WOS:Ferrer, MA | - |
dc.date.coverdate | Febrero 2012 | en_US |
dc.identifier.ulpgc | Sí | es |
dc.description.sjr | 0,668 | |
dc.description.jcr | 1,953 | |
dc.description.sjrq | Q1 | |
dc.description.jcrq | Q3 | |
dc.description.scie | SCIE | |
item.grantfulltext | open | - |
item.fulltext | Con texto completo | - |
crisitem.author.dept | GIR IDeTIC: División de Procesado Digital de Señales | - |
crisitem.author.dept | IU para el Desarrollo Tecnológico y la Innovación | - |
crisitem.author.dept | Departamento de Señales y Comunicaciones | - |
crisitem.author.orcid | 0000-0002-2924-1225 | - |
crisitem.author.parentorg | IU para el Desarrollo Tecnológico y la Innovación | - |
crisitem.author.fullName | Ferrer Ballester, Miguel Ángel | - |
Colección: | Artículos |
Citas SCOPUSTM
11
actualizado el 30-mar-2025
Citas de WEB OF SCIENCETM
Citations
11
actualizado el 30-mar-2025
Visitas
94
actualizado el 31-oct-2024
Descargas
223
actualizado el 31-oct-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.