dc.description.abstractPortable blood glucose meters (PBGMs) allow easy glucose measurements. As animal-specific PBGMs are not available everywhere, those for humans are widely used.Objectives: To assess the accuracy and precision of 9 PBGMs in canine whole blood (WB) and plasma, based on the ISO 15197: 2013.Animals: Fifty-nine client-owned dogs attending the Veterinary Teaching Hospital.Methods: Analytical evaluation of 100 blood samples was performed for accuracy and 23 for precision (glucose 29-579 mg/dL) following ISO recommendations. A PBGM was considered accurate if 95% of the measurements were within +/- 15 mg/dL from the reference when glucose was < 100 mg/dL and within +/- 15% when it was >= 100 mg/dL, and if 99% of them were within zones A and B in error grid analysis (EG). A hexokinase-based analyzer was used as reference. Ninety samples were assessed for hematocrit interferences.Results: Accuracy requirements were not fulfilled by any PBGM in WB (74% of measurements within the limits for the most accurate) and by 1 only in plasma. However, the EG analysis in WB was passed by 6 PBGM and by all in plasma. The most accurate were also the most precise, with coefficients of variation < 5% in WB and < 3% in plasma. Hematocrit correlated with bias against the reference method in 4 PBGM (r = -0.243 - [-0.371]; P <.021).Conclusions and Clinical Importance: This disparity among PBGM suggests that meters approved for humans need to be evaluated before use in other species.en_US
dc.languageengen_US
dc.publisher0891-6640
dc.relation.ispartofJournal of Veterinary Internal Medicineen_US
dc.sourceJournal of Veterinary Internal Medicine [ISSN 0891-6640], v. 28, p. 1405-1413en_US
dc.subject310907 Patologíaen_US
dc.subject.otherPortable Metersen_US
dc.subject.otherBlooden_US
dc.subject.otherCapillaryen_US
dc.subject.otherAnalyzeren_US
dc.subject.otherInsulinen_US
dc.titleISO-Based Assessment of Accuracy and Precision of Glucose Meters in Dogsen_US
dc.typeinfo:eu-repo/semantics/Articleen_US
dc.typeArticleen_US
dc.identifier.doi10.1111/jvim.12397en_US
dc.identifier.scopus84908258300-
dc.identifier.isi000342890900008-
dc.contributor.authorscopusid56236021400-
dc.contributor.authorscopusid56236030500-
dc.contributor.authorscopusid54390208600-
dc.contributor.authorscopusid33068166900-
dc.contributor.authorscopusid56236181000-
dc.contributor.authorscopusid55220360000-
dc.contributor.authorscopusid7401456520-
dc.description.lastpage1413en_US
dc.description.firstpage1405en_US
dc.relation.volume28en_US
dc.investigacionCiencias de la Saluden_US
dc.type2Artículoen_US
dc.contributor.daisngid3255019-
dc.contributor.daisngid15015247-
dc.contributor.daisngid2169777-
dc.contributor.daisngid1964185-
dc.contributor.daisngid12531350-
dc.contributor.daisngid874233-
dc.contributor.daisngid450201-
dc.utils.revisionen_US
dc.contributor.wosstandardWOS:Brito-Casillas, Y-
dc.contributor.wosstandardWOS:Figueirinhas, P-
dc.contributor.wosstandardWOS:Wiebe, JC-
dc.contributor.wosstandardWOS:Lopez-Rios, L-
dc.contributor.wosstandardWOS:Perez-Barreto, D-
dc.contributor.wosstandardWOS:Melian, C-
dc.contributor.wosstandardWOS:Wagner, AM-
dc.date.coverdateEnero 2014en_US
dc.identifier.ulpgcen_US
dc.contributor.buulpgcBU-VETen_US
dc.description.sjr1,261
dc.description.jcr1,879
dc.description.sjrqQ1
dc.description.jcrqQ1
dc.description.scieSCIE
item.grantfulltextnone-
item.fulltextSin texto completo-
crisitem.author.deptGIR IUIBS: Diabetes y endocrinología aplicada-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptGIR IUIBS: Diabetes y endocrinología aplicada-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Patología Animal, Producción Animal, Bromatología y Tecnología de Los Alimentos-
crisitem.author.deptGIR IUIBS: Diabetes y endocrinología aplicada-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Ciencias Médicas y Quirúrgicas-
crisitem.author.orcid0000-0002-0707-7444-
crisitem.author.orcid0000-0002-1496-5706-
crisitem.author.orcid0000-0002-7663-9308-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.fullNameBrito Casillas, Yeray-
crisitem.author.fullNameFigueirinhas Paiva, Pedro-
crisitem.author.fullNameMelián Limiñana, Carlos-
crisitem.author.fullNameWägner, Anna Maria Claudia-
Colección:Artículos
Vista resumida

Citas SCOPUSTM   

20
actualizado el 17-nov-2024

Citas de WEB OF SCIENCETM
Citations

20
actualizado el 17-nov-2024

Visitas

101
actualizado el 15-jun-2024

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.