dc.description.abstractPortable blood glucose meters (PBGMs) allow easy glucose measurements. As animal-specific PBGMs are not available everywhere, those for humans are widely used.Objectives: To assess the accuracy and precision of 9 PBGMs in canine whole blood (WB) and plasma, based on the ISO 15197: 2013.Animals: Fifty-nine client-owned dogs attending the Veterinary Teaching Hospital.Methods: Analytical evaluation of 100 blood samples was performed for accuracy and 23 for precision (glucose 29-579 mg/dL) following ISO recommendations. A PBGM was considered accurate if 95% of the measurements were within +/- 15 mg/dL from the reference when glucose was < 100 mg/dL and within +/- 15% when it was >= 100 mg/dL, and if 99% of them were within zones A and B in error grid analysis (EG). A hexokinase-based analyzer was used as reference. Ninety samples were assessed for hematocrit interferences.Results: Accuracy requirements were not fulfilled by any PBGM in WB (74% of measurements within the limits for the most accurate) and by 1 only in plasma. However, the EG analysis in WB was passed by 6 PBGM and by all in plasma. The most accurate were also the most precise, with coefficients of variation < 5% in WB and < 3% in plasma. Hematocrit correlated with bias against the reference method in 4 PBGM (r = -0.243 - [-0.371]; P <.021).Conclusions and Clinical Importance: This disparity among PBGM suggests that meters approved for humans need to be evaluated before use in other species.en_US
dc.languageengen_US
dc.publisher0891-6640
dc.relation.ispartofJournal of Veterinary Internal Medicineen_US
dc.sourceJournal of Veterinary Internal Medicine [ISSN 0891-6640], v. 28, p. 1405-1413en_US
dc.subject310907 Patologíaen_US
dc.subject.otherPortable Metersen_US
dc.subject.otherBlooden_US
dc.subject.otherCapillaryen_US
dc.subject.otherAnalyzeren_US
dc.subject.otherInsulinen_US
dc.titleISO-Based Assessment of Accuracy and Precision of Glucose Meters in Dogsen_US
dc.typeinfo:eu-repo/semantics/Articleen_US
dc.typeArticleen_US
dc.identifier.doi10.1111/jvim.12397en_US
dc.identifier.scopus84908258300-
dc.identifier.isi000342890900008-
dc.contributor.authorscopusid56236021400-
dc.contributor.authorscopusid56236030500-
dc.contributor.authorscopusid54390208600-
dc.contributor.authorscopusid33068166900-
dc.contributor.authorscopusid56236181000-
dc.contributor.authorscopusid55220360000-
dc.contributor.authorscopusid7401456520-
dc.description.lastpage1413en_US
dc.description.firstpage1405en_US
dc.relation.volume28en_US
dc.investigacionCiencias de la Saluden_US
dc.type2Artículoen_US
dc.contributor.daisngid3255019-
dc.contributor.daisngid15015247-
dc.contributor.daisngid2169777-
dc.contributor.daisngid1964185-
dc.contributor.daisngid12531350-
dc.contributor.daisngid874233-
dc.contributor.daisngid450201-
dc.utils.revisionen_US
dc.contributor.wosstandardWOS:Brito-Casillas, Y-
dc.contributor.wosstandardWOS:Figueirinhas, P-
dc.contributor.wosstandardWOS:Wiebe, JC-
dc.contributor.wosstandardWOS:Lopez-Rios, L-
dc.contributor.wosstandardWOS:Perez-Barreto, D-
dc.contributor.wosstandardWOS:Melian, C-
dc.contributor.wosstandardWOS:Wagner, AM-
dc.date.coverdateEnero 2014en_US
dc.identifier.ulpgcen_US
dc.contributor.buulpgcBU-VETen_US
dc.description.sjr1,261
dc.description.jcr1,879
dc.description.sjrqQ1
dc.description.jcrqQ1
dc.description.scieSCIE
item.grantfulltextnone-
item.fulltextSin texto completo-
crisitem.author.deptGIR IUIBS: Diabetes y endocrinología aplicada-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptGIR IUIBS: Diabetes y endocrinología aplicada-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Patología Animal, Producción Animal, Bromatología y Tecnología de Los Alimentos-
crisitem.author.deptGIR IUIBS: Diabetes y endocrinología aplicada-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Ciencias Médicas y Quirúrgicas-
crisitem.author.orcid0000-0002-0707-7444-
crisitem.author.orcid0000-0002-1496-5706-
crisitem.author.orcid0000-0002-7663-9308-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.fullNameBrito Casillas, Yeray-
crisitem.author.fullNameFigueirinhas Paiva, Pedro-
crisitem.author.fullNameMelián Limiñana, Carlos-
crisitem.author.fullNameWägner, Anna Maria Claudia-
Appears in Collections:Artículos
Show simple item record

SCOPUSTM   
Citations

20
checked on Nov 17, 2024

WEB OF SCIENCETM
Citations

20
checked on Nov 17, 2024

Page view(s)

101
checked on Jun 15, 2024

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.