Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/44171
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Suárez-López, María José | en_US |
dc.contributor.author | Blanco-Marigorta, Ana María | en_US |
dc.contributor.author | Gutiérrez-Trashorras, Antonio José | en_US |
dc.contributor.author | Pistono-Favero, Jorge | en_US |
dc.contributor.author | Blanco-Marigorta, Eduardo | en_US |
dc.contributor.other | Gutierrez Trashorras, Antonio J. | - |
dc.contributor.other | Blanco-Marigorta, Ana M. | - |
dc.contributor.other | Suarez Lopez, Maria Jose | - |
dc.contributor.other | Blanco Marigorta, Eduardo | - |
dc.date.accessioned | 2018-11-21T20:46:18Z | - |
dc.date.available | 2018-11-21T20:46:18Z | - |
dc.date.issued | 2015 | en_US |
dc.identifier.issn | 0196-8904 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/44171 | - |
dc.description.abstract | The solar chimneys used in buildings are passive solar devices which improve natural ventilation. A detailed exergetic analysis has been developed in this work, both for general balance and specific variables. To apply this analysis, a three-dimensional CFD model has been built and validated with bibliographic experimental data. The values of the variables have been examined both inside and at the exit of the solar chimney, resulting in a detailed description of the inner phenomena and parameters influencing the exergetic efficiency. The results of this study offer new tools: a numerical methodology and an exergetic analysis, to improve the design of building ventilation solar chimneys. It also affords a deeper understanding of the thermal and fluid-dynamic behaviour, and suggests some qualitative improvements. However, the numerical data obtained from the case studied, show that solar chimneys as natural ventilation systems offer quite a small efficiency and will remain within the sphere of architectural decisions. | en_US |
dc.language | eng | en_US |
dc.publisher | 0196-8904 | - |
dc.relation.ispartof | Energy Conversion and Management | en_US |
dc.source | Energy Conversion and Management [ISSN 0196-8904], v. 96, p. 1-11 | en_US |
dc.subject | 332201 Distribución de la energía | en_US |
dc.subject | 332203 Generadores de energía | en_US |
dc.subject.other | Solar chimney | en_US |
dc.subject.other | CFD | en_US |
dc.subject.other | Energy-efficient building | en_US |
dc.subject.other | Solar passive design | en_US |
dc.title | Numerical simulation and exergetic analysis of building ventilation solar chimneys | en_US |
dc.type | info:eu-repo/semantics/Article | es |
dc.type | Article | es |
dc.identifier.doi | 10.1016/j.enconman.2015.02.049 | |
dc.identifier.scopus | 84924285983 | - |
dc.identifier.isi | 000353729200001 | - |
dcterms.isPartOf | Energy Conversion And Management | - |
dcterms.source | Energy Conversion And Management[ISSN 0196-8904],v. 96, p. 1-11 | - |
dc.contributor.authorscopusid | 56541689300 | - |
dc.contributor.authorscopusid | 25652860100 | - |
dc.contributor.authorscopusid | 29767561200 | - |
dc.contributor.authorscopusid | 56541774600 | - |
dc.contributor.authorscopusid | 57189341741 | - |
dc.description.lastpage | 11 | - |
dc.description.firstpage | 1 | - |
dc.relation.volume | 96 | - |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Artículo | en_US |
dc.identifier.wos | WOS:000353729200001 | - |
dc.contributor.daisngid | 5506526 | - |
dc.contributor.daisngid | 2029240 | - |
dc.contributor.daisngid | 1693994 | - |
dc.contributor.daisngid | 15034339 | - |
dc.contributor.daisngid | 782862 | - |
dc.identifier.investigatorRID | D-9768-2013 | - |
dc.identifier.investigatorRID | I-5927-2012 | - |
dc.identifier.investigatorRID | G-2555-2016 | - |
dc.identifier.investigatorRID | D-9754-2013 | - |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:Suarez-Lopez, MJ | |
dc.contributor.wosstandard | WOS:Blanco-Marigorta, AM | |
dc.contributor.wosstandard | WOS:Gutierrez-Trashorras, AJ | |
dc.contributor.wosstandard | WOS:Pistono-Favero, J | |
dc.contributor.wosstandard | WOS:Blanco-Marigorta, E | |
dc.date.coverdate | Mayo 2015 | |
dc.identifier.ulpgc | Sí | es |
dc.description.sjr | 2,09 | |
dc.description.jcr | 4,801 | |
dc.description.sjrq | Q1 | |
dc.description.jcrq | Q1 | |
dc.description.scie | SCIE | |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.author.dept | GIR Group for the Research on Renewable Energy Systems | - |
crisitem.author.dept | Departamento de Ingeniería de Procesos | - |
crisitem.author.dept | GIR Group for the Research on Renewable Energy Systems | - |
crisitem.author.dept | Departamento de Ingeniería de Procesos | - |
crisitem.author.orcid | 0000-0003-4635-7235 | - |
crisitem.author.orcid | 0000-0003-4635-7235 | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.fullName | Blanco Marigorta, Ana María | - |
crisitem.author.fullName | Blanco Marigorta, Ana María | - |
Colección: | Artículos |
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.