Identificador persistente para citar o vincular este elemento:
https://accedacris.ulpgc.es/handle/10553/41824
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Ortega, Samuel | en_US |
dc.contributor.author | Fabelo, Himar | en_US |
dc.contributor.author | Camacho, Rafael | en_US |
dc.contributor.author | De la Luz Plaza, María | en_US |
dc.contributor.author | Callicó, Gustavo M. | en_US |
dc.contributor.author | Sarmiento, Roberto | en_US |
dc.date.accessioned | 2018-09-04T09:23:13Z | - |
dc.date.available | 2018-09-04T09:23:13Z | - |
dc.date.issued | 2018 | en_US |
dc.identifier.issn | 2156-7085 | en_US |
dc.identifier.uri | https://accedacris.ulpgc.es/handle/10553/41824 | - |
dc.description.abstract | Hyperspectral imaging (HSI) is an emerging technology for medical diagnosis. This research work presents a proof-of-concept on the use of HSI data to automatically detect human brain tumor tissue in pathological slides. The samples, consisting of hyperspectral cubes collected from 400 nm to 1000 nm, were acquired from ten different patients diagnosed with high-grade glioma. Based on the diagnosis provided by pathologists, a spectral library of normal and tumor tissues was created and processed using three different supervised classification algorithms. Results prove that HSI is a suitable technique to automatically detect high-grade tumors from pathological slides. | en_US |
dc.language | eng | en_US |
dc.relation | HypErspectraL Imaging Cancer Detection (HELiCoiD) (CONTRATO Nº 618080) | en_US |
dc.relation.ispartof | Biomedical Optics Express | en_US |
dc.source | Biomedical Optics Express [ISSN 2156-7085], v. 9(2), 309085, p. 818-831 | en_US |
dc.subject | 220921 Espectroscopia | en_US |
dc.subject | 32 Ciencias médicas | en_US |
dc.subject.other | Multispectral and hyperspectral imaging | en_US |
dc.subject.other | Medical optics and biotechnology | en_US |
dc.subject.other | Optical pathology | en_US |
dc.subject.other | Spectroscopy, tissue diagnostics | en_US |
dc.subject.other | Tissue characterization | en_US |
dc.title | Detecting brain tumor in pathological slides using hyperspectral imaging | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1364/BOE.9.000818 | en_US |
dc.identifier.scopus | 85041547891 | - |
dc.identifier.isi | 000425923300038 | - |
dc.contributor.authorscopusid | 57189334144 | - |
dc.contributor.authorscopusid | 56405568500 | - |
dc.contributor.authorscopusid | 57213808968 | - |
dc.contributor.authorscopusid | 57204257416 | - |
dc.contributor.authorscopusid | 56006321500 | - |
dc.contributor.authorscopusid | 35609452100 | - |
dc.description.lastpage | 831 | en_US |
dc.identifier.issue | 2 | - |
dc.description.firstpage | 818 | en_US |
dc.relation.volume | 9 | en_US |
dc.investigacion | Ciencias de la Salud | en_US |
dc.type2 | Artículo | en_US |
dc.contributor.daisngid | 1812298 | - |
dc.contributor.daisngid | 2096372 | - |
dc.contributor.daisngid | 2153004 | - |
dc.contributor.daisngid | 9355820 | - |
dc.contributor.daisngid | 506422 | - |
dc.contributor.daisngid | 116294 | - |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:Ortega, S | - |
dc.contributor.wosstandard | WOS:Fabelo, H | - |
dc.contributor.wosstandard | WOS:Camacho, R | - |
dc.contributor.wosstandard | WOS:Plaza, MD | - |
dc.contributor.wosstandard | WOS:Callico, GM | - |
dc.contributor.wosstandard | WOS:Sarmiento, R | - |
dc.date.coverdate | Febrero 2018 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-MED | en_US |
dc.description.sjr | 1,516 | |
dc.description.jcr | 3,91 | |
dc.description.sjrq | Q1 | |
dc.description.jcrq | Q1 | |
dc.description.scie | SCIE | |
item.fulltext | Con texto completo | - |
item.grantfulltext | open | - |
crisitem.author.dept | GIR IUMA: Diseño de Sistemas Electrónicos Integrados para el procesamiento de datos | - |
crisitem.author.dept | IU de Microelectrónica Aplicada | - |
crisitem.author.dept | GIR IUMA: Diseño de Sistemas Electrónicos Integrados para el procesamiento de datos | - |
crisitem.author.dept | IU de Microelectrónica Aplicada | - |
crisitem.author.dept | GIR IUMA: Diseño de Sistemas Electrónicos Integrados para el procesamiento de datos | - |
crisitem.author.dept | IU de Microelectrónica Aplicada | - |
crisitem.author.dept | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.dept | GIR IUMA: Diseño de Sistemas Electrónicos Integrados para el procesamiento de datos | - |
crisitem.author.dept | IU de Microelectrónica Aplicada | - |
crisitem.author.dept | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.orcid | 0000-0002-7519-954X | - |
crisitem.author.orcid | 0000-0002-9794-490X | - |
crisitem.author.orcid | 0000-0002-3784-5504 | - |
crisitem.author.orcid | 0000-0002-4843-0507 | - |
crisitem.author.parentorg | IU de Microelectrónica Aplicada | - |
crisitem.author.parentorg | IU de Microelectrónica Aplicada | - |
crisitem.author.parentorg | IU de Microelectrónica Aplicada | - |
crisitem.author.parentorg | IU de Microelectrónica Aplicada | - |
crisitem.author.fullName | Ortega Sarmiento,Samuel | - |
crisitem.author.fullName | Fabelo Gómez, Himar Antonio | - |
crisitem.author.fullName | Marrero Callicó, Gustavo Iván | - |
crisitem.author.fullName | Sarmiento Rodríguez, Roberto | - |
crisitem.project.principalinvestigator | Marrero Callicó, Gustavo Iván | - |
Colección: | Artículos |
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.