dc.description.abstractA swimming pool in Corrales de Buelna (Cantabria) was demolished in March 2017 due to the loss of mechanical performance of the laminated timber structure. The relevant deterioration was caused by rotting of the wood and corrosion of the metal connecting elements. The structure featured a barrel vault with five large tri-articulated arches enclosed on the sides by inclined facades formed by toral rafters and purlins. The corresponding diagnostic process involved data collection and structural assessments to verify the structure’s bearing capacity and serviceability. Data collection was carried out in December 2015 and consisted of a thermal camera inspection to determine the points of moisture accumulation and sampling openings, conduct environmental and wood hygrothermal measurements, and measure cross-sectional losses and deformations of the structural elements. Verification of the load-bearing capacity was carried out using matrix calculation structure software for both the original and deteriorated structure. The diagnosis indicated that the damage was caused by leaks in the joints of the aluminum composite roof panels and by the insufficient load-bearing capacity of the structure. The severity of the damage compromised the mechanical strength and stability of the building, leading to a recommendation that the use of the facilities be immediately discontinued. The degree of deterioration left the structure unrecoverable, making it very difficult to apply reinforcement measures. These factors led to the structure’s demolition to prevent its collapse. en_US
dc.languagespaen_US
dc.relation.ispartofBuildingsen_US
dc.subject6201 Arquitecturaen_US
dc.titleStructural Deterioration and Failure of the Laminated Wooden Roof of a Covered Swimming Poolen_US
dc.typeArticleen_US
dc.identifier.doi10.3390/buildings14123794en_US
dc.description.lastpage18en_US
dc.identifier.issue12-
dc.description.firstpage1en_US
dc.investigacionIngeniería y Arquitecturaen_US
dc.description.numberofpages18en_US
dc.utils.revisionen_US
dc.identifier.ulpgcen_US
dc.contributor.buulpgcBU-ARQen_US
item.grantfulltextopen-
item.fulltextCon texto completo-
crisitem.author.deptGIR TIDES: URSCAPES-
crisitem.author.deptIU de Turismo y Desarrollo Económico Sostenible-
crisitem.author.deptDepartamento de Construcción Arquitectónica-
crisitem.author.orcid0000-0002-5826-4653-
crisitem.author.parentorgIU de Turismo y Desarrollo Económico Sostenible-
crisitem.author.fullNamePinilla Melo,Javier-
crisitem.author.fullNameFlores Medina, Nelson-
Appears in Collections:Artículos
Adobe PDF (4,26 MB)
Show simple item record

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.