Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/70158
Título: | Does the modelling of the pectus bar affect its stability? Rationale for using a short flat bar | Autores/as: | Pérez, David Martel, Oscar Yánez, Alejandro Cano, José R. Cuadrado, Alberto Torrent, Gara López, Luis |
Clasificación UNESCO: | 3313 Tecnología e ingeniería mecánicas | Palabras clave: | Finite Element Analysis Nuss Procedure Pectus Excavatum |
Fecha de publicación: | 2020 | Publicación seriada: | Interactive Cardiovascular and Thoracic Surgery | Resumen: | OBJECTIVES: Although the Nuss procedure for pectus excavatum is still associated with a non-negligible risk of postoperative bar displacement, the potential effects of the length and shape of the bar on its corrective ability and stability have not been sufficiently studied. The aim of this study was to determine how the modelling of the pectus bar affects its stability and whether an alternative configuration of the implant can improve clinical success. METHODS: Simulated implantation of bars with different shapes and sizes in a computational model was carried out. A 250 N sternal force was applied to the bars, and the resulting forces and moments on the fixation points were identified. Afterwards, a clinical trial was carried out in a group of patients with pectus excavatum, some of whom received long inverted U-shaped bars and some of whom received implants designed from the computational results. RESULTS: When U-shaped bars were tested, the sternal force generated unbalanced horizontal reaction forces (16 vs 61 N) and large reaction moments at the ends of the bar, conferring the tendency to slide and to rotate, respectively. No lateral or rotational destabilizing forces occurred in the case of a flat bar. Cosmetic outcomes, postoperative times and hospital stays were similar in both clinical groups. However, 2 cases (2/15) of bar flipping occurred in patients who received the conventional bar. CONCLUSIONS: The shape of the bar is a determinant of its stability. A flat, shorter pectus bar provides adequate correction of the deformity with less tendency for bar displacement in the repair of pectus excavatum. | URI: | http://hdl.handle.net/10553/70158 | ISSN: | 1569-9293 | DOI: | 10.1093/icvts/ivz217 | Fuente: | Interactive cardiovascular and thoracic surgery [ISSN 1569-9293], v. 30 (1), p. 11-17 |
Colección: | Artículos |
Citas SCOPUSTM
5
actualizado el 17-nov-2024
Citas de WEB OF SCIENCETM
Citations
3
actualizado el 17-nov-2024
Visitas
113
actualizado el 09-mar-2024
Descargas
50
actualizado el 09-mar-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.