Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/70017
Título: Nodal staging in the rectal cancer follow-up MRI after chemoradiotherapy: use of morphology, size, and diffusion criteria
Autores/as: Fornell-Perez, R.
Pérez Alonso, Esteban 
Alemán-Flores, Patricia
Lozano-Rodriguez, A.
Loro Ferrer, Juan Francisco 
Clasificación UNESCO: 320111 Radiología
Palabras clave: Total Mesorectal Excision
Lymph-Nodes
Chemoradiation
Accuracy
Validation, et al.
Fecha de publicación: 2020
Publicación seriada: Clinical radiology (Harlow. Print) 
Resumen: To analyse changes in post-neoadjuvant follow-up magnetic resonance imaging (MRI) staging accuracy for malignant adenopathies in rectal cancer, by comparing size criteria with morphological criteria using high-resolution T2-weighted sequences, as well as variations when adding diffusion-weighted imaging. METHODS AND MATERIALS: The present study was a cross-sectional study of a database including 46 1.5-T MRI examinations (2011–2016) from patients with biopsy-proven rectal cancer and chemoradiotherapy treatment before surgery. All cases were reviewed by three radiologists individually, who were blinded to any clinical information. The radiologists were experienced in rectal cancer (3–6 years) and evaluated the presence of malignant nodes in each patient. Malignancy was determined using morphological, size (5 mm), and diffusion criteria separately, as well as morphology plus diffusion. Each case was assessed four times: (1) evaluation of morphological criteria; (2) size criteria; (3) evaluation only using diffusion (b-values 50, 400, and 800); and (4) diffusion plus morphological criteria. Histological staging of surgical specimens was the reference standard. Statistical analysis included accuracy (area under the receiver operating characteristic [ROC] curve [AUC]), sensitivity, specificity, and positive/negative predictive values (PPV/NPV) for each radiologist, and group agreement (Fleiss' kappa). RESULTS: Mean values using morphological criteria were: AUC 0.78, sensitivity 77.7%, specificity 73.8%, PPV 66.1%, NPV 85.2%. Using size criterion: AUC 0.75, sensitivity 62.9%, specificity 83.2%, PPV 74.1%, NPV 80%. Added diffusion yielded no improvement, and yielded worse results by itself. CONCLUSIONS: Although morphological criteria showed better results in accuracy, sensitivity, and NPV, size criterion yielded the best specificity and PPV. Adding diffusion did not demonstrate a clear advantage over the criteria by themselves. Thus, mixed size–morphology criteria could have the greatest diagnostic value for follow-up N-staging.
URI: http://hdl.handle.net/10553/70017
ISSN: 0009-9260
DOI: 10.1016/j.crad.2019.08.003
Fuente: Clinical Radiology [ISSN 0009-9260], v. 75 (2), p. 100-107
Colección:Artículos
Vista completa

Citas SCOPUSTM   

4
actualizado el 17-nov-2024

Citas de WEB OF SCIENCETM
Citations

5
actualizado el 17-nov-2024

Visitas

74
actualizado el 14-oct-2023

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.