Título: | Symbolic dynamics marker of heart rate variability combined with clinical variables enhance obstructive sleep apnea screening | Autores/as: | Ravelo-García, A. G. Saavedra-Santana, P. Juliá-Serdá, G. Navarro-Mesa, J. L. Navarro-Esteva, J. Álvarez-López, X. Gapelyuk, A. Penzel, T. Wessel, N. |
Palabras clave: | Electroencephalography Multivariate analysis Nonlinear dynamics |
Fecha de publicación: | 2014 | Publicación seriada: | Chaos | Resumen: | Many sleep centres try to perform a reduced portable test in order to decrease the number of overnight polysomnographies that are expensive, time-consuming, and disturbing. With some limitations, heart rate variability (HRV) has been useful in this task. The aim of this investigation was to evaluate if inclusion of symbolic dynamics variables to a logistic regression model integrating clinical and physical variables, can improve the detection of subjects for further polysomnographies. To our knowledge, this is the first contribution that innovates in that strategy. A group of 133 patients has been referred to the sleep center for suspected sleep apnea. Clinical assessment of the patients consisted of a sleep related questionnaire and a physical examination. The clinical variables related to apnea and selected in the statistical model were age (p < 10(-3)), neck circumference (p < 10(-3)), score on a questionnaire scale intended to quantify daytime sleepiness (p < 10(-3)), and intensity of snoring (p < 10(-3)). The validation of this model demonstrated an increase in classification performance when a variable based on non-linear dynamics of HRV (p < 0.01) was used additionally to the other variables. For diagnostic rule based only on clinical and physical variables, the corresponding area under the receiver operating characteristic (ROC) curve was 0.907 (95% confidence interval (CI) = 0.848, 0.967), (sensitivity 87.10% and specificity 80%). For the model including the average of a symbolic dynamic variable, the area under the ROC curve was increased to 0.941 (95% = 0.897, 0.985), (sensitivity 88.71% and specificity 82.86%). In conclusion, symbolic dynamics, coupled with significant clinical and physical variables can help to prioritize polysomnographies in patients with a high probability of apnea. In addition, the processing of the HRV is a well established low cost and robust technique. | URI: | http://hdl.handle.net/10553/52453 | ISSN: | 1054-1500 | DOI: | 10.1063/1.4869825 | Fuente: | Chaos[ISSN 1054-1500],v. 24 (2), (Junio 2014) |
Colección: | Artículos |
Citas SCOPUSTM
30
actualizado el 15-dic-2024
Citas de WEB OF SCIENCETM
Citations
27
actualizado el 15-dic-2024
Visitas
88
actualizado el 21-sep-2024
Descargas
266
actualizado el 21-sep-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.