Título: | Comparative study of the electrochemical behaviour of sepiolite and hectorite modified carbon paste electrodes in the determination of dinocap | Autores/as: | Hernandez, Lucas Hernandez, Pedro Lorenzo, Encarnacion Ferrera, Zoraida Sosa |
Clasificación UNESCO: | 2301 química analítica | Palabras clave: | Modified carbon paste electrodes Differential-pulse voltammetry Dinocap determination |
Fecha de publicación: | 1988 | Editor/a: | 0003-2654 | Publicación seriada: | Analyst (London. 1877. Print) | Resumen: | A comparative study of the electrochemical behaviour of sepiolite and hectorite modified carbon paste electrodes in the determination of dinocap has been carried out. Dinocap was adsorbed on the electrodes in an open circuit (pH 4.0) and was determined by differential-pulse voltammetry at pH 5.3 in 0.5 M KNO3. The calibration graph obtained is linear for 2–14 ng ml–1 of dinocap using the sepiolite modified electrode and for 18–72 ng ml–1 of dinocap using the hectorite modified electrode. | URI: | http://hdl.handle.net/10553/49128 | ISSN: | 0003-2654 | DOI: | 10.1039/AN9881300621 | Fuente: | The Analyst [ISSN 0003-2654], v. 113, p. 621-623 |