Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/48335
Título: | Dual Intragastric Balloon: Single Ambulatory Center Spanish Experience with 60 Patients in Endoscopic Weight Loss Management | Autores/as: | Lopez-Nava, G. Bautista-Castaño, I. Jimenez-Baños, A. Fernandez-Corbelle, J. P. |
Clasificación UNESCO: | 32 Ciencias médicas 3213 Cirugía |
Palabras clave: | Dual intragastric balloon Bariatric endoscopy Obesity treatment |
Fecha de publicación: | 2015 | Publicación seriada: | Obesity Surgery | Resumen: | Background Many obese patients fail conventional medical management and decline bariatric surgery. Less invasive weight loss options such as intragastric balloons may provide an opportunity to reach this large number of untreated patients. The aim of this study was to investigate the safety and effectiveness of the Dual Intragastric Balloon (DIGB) in the treatment of obese patients, as well as the impact of degree of obesity, age, and gender. Methods The study was conducted at the Bariatric Endoscopy Unit of the Madrid Sanchinarro University Hospital. Sixty patients (11 men, 49 women) underwent endoscopic placement of a DIGB filled with a total of 900 cc of saline (450 cc in each balloon) for at least 6 months, along with regular counseling from a multidisciplinary team. Study outcomes included: change in body weight (TBWL), % of loss of initial body weight (%TBWL), % of excess body weight loss (%EWL), and adverse events. Results Initial BMI 38.8 kg/m2 decreased 6.1 units, with mean TBWL, %TBWL, and %EWL of 16.6 kg, 15.4 %, and 47.1 %, respectively. We found no difference in %TBWL between grade of obesity, age or sex, but morbidly obese patients demonstrated greater TBWL, and women and less obese subjects obtained higher %EWL. The DIGB was generally well tolerated, with one early removal for patient intolerance, one early deflation without migration, and one gastric perforation. Fourteen patients had small, clinically insignificant ulcers or erosions noted at the time of removal. Conclusions The present study shows that the DIGB was easy to use, resulted in significant weight loss, safe, and well tolerated. | URI: | http://hdl.handle.net/10553/48335 | ISSN: | 0960-8923 | DOI: | 10.1007/s11695-015-1715-6 | Fuente: | Obesity Surgery[ISSN 0960-8923],v. 25, p. 2263-2267 (mayo 2015) |
Colección: | Artículos |
Citas SCOPUSTM
43
actualizado el 01-dic-2024
Citas de WEB OF SCIENCETM
Citations
39
actualizado el 24-nov-2024
Visitas
91
actualizado el 06-jul-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.