Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/47076
Título: | Magnetic resonance imaging study in a normal Bengal tiger (Panthera tigris) stifle joint | Autores/as: | Arencibia Espinosa, Alberto Encinoso Quintana, Mario Óscar Jáber Mohamad, José Raduán Morales, Daniel Blanco Sucino, Diego Artiles Vizcaíno, Alejandro Vázquez Autón,José Maria |
Clasificación UNESCO: | 2401 Biología animal (zoología) 240101 Anatomía animal 310901 Anatomía |
Palabras clave: | Magnetic resonance imaging Anatomy Stifle joint Tiger |
Fecha de publicación: | 2015 | Publicación seriada: | BMC Veterinary Research | Resumen: | Background: The purpose of this study was to describe the normal appearance of the bony and soft tissue structures of the stifle joint of a Bengal tiger (Panthera tigris) by low-field magnetic resonance imaging (MRI), and the use of gross anatomical dissections performed as anatomical reference. A cadaver of a mature female was imaged by MRI using specific sequences as the Spin-echo (SE) T1-weighting and Gradient-echo (GE) STIR T2-weighting sequences in sagittal, dorsal and transverse planes, with a magnet of 0.2 Tesla. The bony and articular structures were identified and labelled on anatomical dissections, as well as on the magnetic resonance (MR) images. Results: MR images showed the bone, articular cartilage, menisci and ligaments of the normal tiger stifle. SE T1-weighted sequence provided excellent resolution of the subchondral bones of the femur, tibia and patella compared with the GE STIR T2-weighted MR images. Articular cartilage and synovial fluid were visualised with high signal intensity in GE STIR T2-weighted sequence, compared with SE T1-weighted sequence where they appeared with intermediate intensity signal. Menisci and ligaments of the stifle joint were visible with low signal intensity in both sequences. The infrapatellar fat pad was hyperintense on SE T1-weighted images and showed low signal intensity on GE STIR T2-weighted images. Conclusions: MRI provided adequate information of the bony and soft tissues structures of Bengal tiger stifle joints. This information can be used as initial anatomic reference for interpretation of MR stifle images and to assist in the diagnosis of diseases of this region. | URI: | http://hdl.handle.net/10553/47076 | ISSN: | 1746-6148 | DOI: | 10.1186/s12917-015-0532-4 | Fuente: | BMC Veterinary Research [ISSN 1746-6148], v. 11 (192), p. 1-9 |
Colección: | Artículos |
Citas SCOPUSTM
8
actualizado el 15-dic-2024
Citas de WEB OF SCIENCETM
Citations
8
actualizado el 15-dic-2024
Visitas
144
actualizado el 12-oct-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.