Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/45362
Título: | Evaluation of pulmonary function variables by using plethysmography in cats with respiratory disease associated to Dirofilaria immitis | Autores/as: | García-Guasch, L. Caro Vadillo, Alicia Manubens-Grau, J. Carretón Gomez, Elena Morchon Garcia,Rodrigo Simón Martín,Fernando Montoya Alonso, José Alberto |
Clasificación UNESCO: | 310907 Patología 240112 Parasitología animal |
Palabras clave: | Dirofilaria immitis Feline heartworm Plethysmography Heartworm associated respiratory disease |
Fecha de publicación: | 2012 | Editor/a: | 0304-4017 | Publicación seriada: | Veterinary Parasitology | Resumen: | Heartworm Associated Respiratory Disease (HARD) is a pulmonary syndrome that results from the vascular and parenchymal inflammatory response associated with the arrival and death of Dirofilaria immitis in the distal pulmonary arteries. Barometric whole-body plethysmography (BWBP) is a non-invasive pulmonary function test (PFT) that allows a dynamic study of breathing patterns and is useful to study airway disease and the response to different treatments. The aim of this prospective non-blinded study was to compare respiratory function variables between healthy cats and HARD cats (seropositive to D. immitis) by use of BWBP. Twenty-five healthy cats and six HARD cats were put into the plethysmograph chamber and different respiratory variables were measured. The results were analyzed and compared between the two groups of animals. There were significant differences for bronchoconstriction index variables Pause (P-value < 0.001) and enhanced pause (P-value < 0.001), minute volume (P-value < 0.05) and tidal volume (P-value < 0.05) between healthy and HARD cats. There were no significant differences in respiratory rate and inspiratory and expiratory times between both groups of animals. The results obtained in our study support that HARD cats show significant differences in pulmonary function variables obtained by BWBP due to an acute inflammatory response at bronchial, vascular and parenchymal level. This PFT could be a useful method to facilitate the diagnosis of pathological states of bronchoconstriction in HARD cats. | URI: | http://hdl.handle.net/10553/45362 | ISSN: | 0304-4017 | DOI: | 10.1016/j.vetpar.2011.12.013 | Fuente: | Veterinary Parasitology [ISSN 0304-4017], v. 187, p. 254-258 |
Colección: | Artículos |
Citas SCOPUSTM
17
actualizado el 15-dic-2024
Citas de WEB OF SCIENCETM
Citations
17
actualizado el 15-dic-2024
Visitas
80
actualizado el 04-may-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.