Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/45331
Título: Simultaneous determination of seven β2-agonists in human and bovine urine by isotope dilution liquid chromatography-tandem mass spectrometry using compound-specific minimally 13C-labelled analogues
Autores/as: González-Antuña, Ana 
Rodríguez-González, Pablo
Centineo, Giuseppe
García Alonso, J. Ignacio
Clasificación UNESCO: 32 Ciencias médicas
230103 Análisis cromatográfico
230110 Espectroscopia de masas
Palabras clave: Isotope dilution
Liquid chromatography
Matrix effects
Minimal labeling
Selected reaction monitoring, et al.
Fecha de publicación: 2014
Publicación seriada: Journal of Chromatography A 
Resumen: Seven β2-agonist (clenproperol, clenbuterol, salbutamol, bronbuterol, ractopamine, clenpenterol and clencyclohexerol) were determined simultaneously in human and bovine urine by isotope dilution LC-ESI-MS/MS in a triple quadrupole instrument. The method is based on the application of multiple linear regression in combination with compound-specific minimally 13C-labelled analogues. Additionally, the increase of the bandpass of the first quadrupole during the selected reaction monitoring (SRM) measurement procedure allowed the simultaneous quantification of the seven compounds at sub ngg-1 levels in a single chromatogram without resorting to a methodological calibration graph. Recovery values at concentration levels between 5.0 and 0.05ngg-1 ranged from 95 to 110% in fortified bovine urine and from 91 to 108% in human urine, with relative standard deviations lower than 5% except for salbutamol and ractopamine. The proposed methodology was validated by analyzing the certified reference material BCR-503 (lyophilized bovine urine) certified for clenbuterol and salbutamol. The limits of detection (LOD) for a sample volume of 10mL of both human and bovine urine was found to be lower than 0.012ngg-1 for all compounds, except to salbutamol in bovine urine which was of 0.029ngg-1. The use of compound-specific isotopically labelled analogues minimally labelled in 13C minimized the occurrence of isotope effects and corrected for matrix effects during ESI ionization and can be efficiently applied for the quantification of ultra-trace concentrations of β2-agonists in human and bovine urine.
URI: http://hdl.handle.net/10553/45331
ISSN: 0021-9673
DOI: 10.1016/j.chroma.2014.10.065
Fuente: Journal of Chromatography A [ISSN 0021-9673], v. 1372, p. 63-71
Colección:Artículos
Vista completa

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.