Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/35710
Título: | Computational characterization of HPGe detectors usable for a wide variety of source geometries by using Monte Carlo simulation and a multi-objective evolutionary algorithm | Autores/as: | González Guerra, Jonay García Rubiano, Jesús Winter Althaus, Gabriel González Guerra, Antonio Alonso Hernández, Héctor Arnedo Ayensa, Miguel Ángel Tejera-Cruz, Alicia Martel Escobar, Pablo Bolivar, J. P. |
Clasificación UNESCO: | 120601 Construcción de algoritmos 1206 Análisis numérico 120326 Simulación |
Palabras clave: | HPGe detectors Efficiency calibration Monte Carlo simulation Marinelli beakers Differential evolution multi-objective, et al. |
Fecha de publicación: | 2017 | Publicación seriada: | Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | Resumen: | In this work, we have developed a computational methodology for characterizing HPGe detectors by implementing in parallel a multi-objective evolutionary algorithm, together with a Monte Carlo simulation code. The evolutionary algorithm is used for searching the geometrical parameters of a model of detector by minimizing the differences between the efficiencies calculated by Monte Carlo simulation and two reference sets of Full Energy Peak Efficiencies (FEPEs) corresponding to two given sample geometries, a beaker of small diameter laid over the detector window and a beaker of large capacity which wrap the detector. This methodology is a generalization of a previously published work, which was limited to beakers placed over the window of the detector with a diameter equal or smaller than the crystal diameter, so that the crystal mount cap (which surround the lateral surface of the crystal), was not considered in the detector model. The generalisation has been accomplished not only by including such a mount cap in the model, but also using multi-objective optimization instead of mono-objective, with the aim of building a model sufficiently accurate for a wider variety of beakers commonly used for the measurement of environmental samples by gamma spectrometry, like for instance, Marinellis, Petris, or any other beaker with a diameter larger than the crystal diameter, for which part of the detected radiation have to pass through the mount cap. The proposed methodology has been applied to an HPGe XtRa detector, providing a model of detector which has been successfully verificated for different source detector geometries and materials and experimentally validated using CRMs. | URI: | http://hdl.handle.net/10553/35710 | ISSN: | 0168-9002 | DOI: | 10.1016/j.nima.2017.02.087 | Fuente: | Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment [ISSN 0168-9002], v. 858, p. 113-122 |
Colección: | Artículos |
Citas SCOPUSTM
17
actualizado el 15-dic-2024
Citas de WEB OF SCIENCETM
Citations
16
actualizado el 15-dic-2024
Visitas
135
actualizado el 16-mar-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.