Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/35296
Título: | Reliability and measurement error of tensiomyography to assess mechanical muscle function: A systematic review | Autores/as: | Martín Rodríguez, Saúl Loturco, Irineu Hunter, Angus M. Munguia-Izquierdo, Diego Rodríguez-Ruiz, David |
Clasificación UNESCO: | 241106 Fisiología del ejercicio 320404 Rehabilitación (médica) 241110 Fisiología del músculo |
Palabras clave: | Muscle contractile properties Relative reliability Absolute reliability |
Fecha de publicación: | 2017 | Publicación seriada: | Journal of Strength and Conditioning Research | Resumen: | Interest in studying mechanical skeletal muscle function through tensiomyography (TMG) has increased in recent years. This systematic review aimed to (a) report the reliability and measurement error of all TMG parameters (i.e., maximum radial displacement of the muscle belly [Dm], contraction time [Tc], delay time [Td], half-relaxation time [½ Tr], and sustained contraction time [Ts]) and (b) to provide critical reflection on how to perform accurate and appropriate measurements for informing clinicians, exercise professionals, and researchers. A comprehensive literature search was performed of the Pubmed, Scopus, Science Direct, and Cochrane databases up to July 2017. Eight studies were included in this systematic review. Meta-analysis could not be performed because of the low quality of the evidence of some studies evaluated. Overall, the review of the 9 studies involving 158 participants revealed high relative reliability (intraclass correlation coefficient [ICC]) for Dm (0.91–0.99); moderate-to-high ICC for Ts (0.80–0.96), Tc (0.70–0.98), and ½ Tr (0.77–0.93); and low-to-high ICC for Td (0.60–0.98), independently of the evaluated muscles. In addition, absolute reliability (coefficient of variation [CV]) was low for all TMG parameters except for ½ Tr (CV = .20%), whereas measurement error indexes were high for this parameter. In conclusion, this study indicates that 3 of the TMG parameters (Dm, Td, and Tc) are highly reliable, whereas ½ Tr demonstrate insufficient reliability, and thus should not be used in future studies. | URI: | http://hdl.handle.net/10553/35296 | ISSN: | 1064-8011 | DOI: | 10.1519/JSC.0000000000002250 | Fuente: | Journal of Strength and Conditioning Research [ISSN 1064-8011], v. 31 (12), p. 3524-3536 |
Colección: | Reseña |
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.