Título: | Minimum intraoperative testing battery for cochlear implantation: the international practice trend | Autores/as: | Aljazeeri, Isra Abdelsamad, Yassin Alsanosi, Abdulrahman Hagr, Abdulrahman Kim, Ana H. Ramos Macías, Ángel Manuel Ramos De Miguel, Ángel Kurz, Anja Lorens, Artur Gantz, Bruce Buchman, Craig A. Távora-Vieira, Dayse Sprinzl, Georg Mertens, Griet Saunders, James E. Kosaner, Julie Telmesani, Laila M. Lassaletta, Luis Bance, Manohar Yousef, Medhat Holcomb, Meredith A. Adunka, Oliver Cayé-Thomasen, Per Skarzynski, Piotr Henryk Rajeswaran, Ranjith Briggs, Robert J. Oh, Seung Ha Plontke, Stefan K. O’Leary, Stephen J. Agrawal, Sumit Yamasoba, Tatsuya Lenarz, Thomas Wesarg, Thomas Kutz, Walter Connolly, Patrick Anderson, Ilona Alzhrani, Farid |
Clasificación UNESCO: | 321305 Cirugía de garganta, nariz y oídos | Palabras clave: | Cochlear Implantation Ecap Fnm Impedance Intraoperative Testing, et al. |
Fecha de publicación: | 2024 | Publicación seriada: | European Archives of Oto-Rhino-Laryngology | Resumen: | Purpose: In cochlear implantation (CI) surgery, there are a wide variety of intraoperative tests available. However, no clear guide exists on which tests must be performed as the minimum intraoperative testing battery. Toward this end, we studied the usage patterns, recommendations, and attitudes of practitioners toward intraoperative testing. Methods: This study is a multicentric international survey of tertiary referral CI centers. A survey was developed and administered to a group of CI practitioners (n = 34) including otologists, audiologists and biomedical engineers. Thirty six participants were invited to participate in this study based on a their scientific outputs to the literature on the intraoperative testing in CI field and based on their high load of CI surgeries. Thirty four, from 15 countries have accepted the invitation to participate. The participants were asked to indicate the usage trends, perceived value, influence on decision making and duration of each intraoperative test. They were also asked to indicate which tests they believe should be included in a minimum test battery for routine cases. Results: Thirty-two (94%) experts provided responses. The most frequently recommended tests for a minimum battery were facial nerve monitoring, electrode impedance measurements, and measurements of electrically evoked compound action potentials (ECAPs). The perceived value and influence on surgical decision-making also varied, with high-resolution CT being rated the highest on both measures. Conclusion: Facial nerve monitoring, electrode impedance measurements, and ECAP measurements are currently the core tests of the intraoperative test battery for CI surgery. | URI: | http://hdl.handle.net/10553/134394 | ISSN: | 0937-4477 | DOI: | 10.1007/s00405-024-08944-y | Fuente: | European Archives of Oto-Rhino-Laryngology [ISSN 0937-4477], (Enero 2024) |
Colección: | Artículos |
Visitas
29
actualizado el 26-oct-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.