Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/131192
Título: Characterization of wash-off from urban impervious surfaces and SuDS design criteria for source control under semi-arid conditions
Autores/as: Andrés-Doménech, Ignacio
Hernández-Crespo, Carmen
Vega Martin, Miguel Ángel 
Andres Valeri, Valerio Carlos 
Clasificación UNESCO: 330506 Ingeniería civil
Palabras clave: Semi-arid conditions
SuDS design criteria
Urban impervious surfaces
Wash-off
Wash-off modelling
Fecha de publicación: 2018
Publicación seriada: Science of the Total Environment 
Resumen: Knowledge about pollutant wash-off from urban impervious surfaces is a key feature for developing effective management strategies. Accordingly, further information is required about urban areas under semi-arid climate conditions at the sub-catchment scale. This is important for designing source control systems for pollution. In this study, a characterization of pollutant wash-off has been performed over sixteen months, at the sub-catchment scale for urban roads as impervious surfaces. The study was conducted in Valencia, Spain, a city with a Mediterranean climate. The results show high event mean concentrations for suspended solids (98 mg/l), organic matter (142 mg COD/l, 25 mg BOD5/l), nutrients (3.7 mg TN/l, 0.4 mg TP/l), and metals (0.23, 0.32, 0.62 and 0.17 mg/l for Cu, Ni, Pb, and Zn, respectively). The results of the runoff characterization highlight the need to control this pollution at its source, separately from wastewater because of their different characteristics. The wash-off, defined in terms of mobilized mass (g/m2) fits well with both process-based and statistical models, with the runoff volume and rainfall depth being the main explanatory variables. Based on these results and using information collected from hydrographs and pollutographs, an approach for sizing sustainable urban drainage systems (SuDS), focusing on water quality and quantity variables, has been proposed. By setting a concentration-based target (TSS discharged to receiving waters < 35 mg/l), the results indicate that for a SuDS type detention basin (DB), an off-line configuration performs better than an on-line configuration. The resulting design criterion, expressed as SuDS volume per unit catchment area, assuming a DB type SuDS, varies between 7 and 10 l/m2.
URI: http://hdl.handle.net/10553/131192
ISSN: 0048-9697
DOI: 10.1016/j.scitotenv.2017.09.011
Fuente: Science of the Total Environment [0048-9697] , v. 612, p. 1320-1328 (Enero 2018)
Colección:Artículos
Vista completa

Citas SCOPUSTM   

33
actualizado el 17-nov-2024

Citas de WEB OF SCIENCETM
Citations

30
actualizado el 17-nov-2024

Visitas

40
actualizado el 28-sep-2024

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.