Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/128474
Título: Reduced desalination carbon footprint on islands with weak electricity grids. The case of Gran Canaria
Autores/as: Cabrera Santana, Pedro Jesús 
Carta González, José Antonio 
Matos Sánchez, Carlos 
Rosales Asensio, Enrique 
Henrik Lund
Clasificación UNESCO: 332205 Fuentes no convencionales de energía
3313 Tecnología e ingeniería mecánicas
3306 Ingeniería y tecnología eléctricas
330806 Regeneración del agua
Palabras clave: On-grid wind desalination
Off-grid wind desalination
Zero-carbon footprint
Reverse osmosis
Desalination, et al.
Fecha de publicación: 2024
Proyectos: Investigación e innovación hacia la Excelencia en Eficiencia tecnológica, uso de Energías renovables, tecnologías Emergentes y Economía circular en la DESalación 
Publicación seriada: Applied Energy 
Resumen: The aim of this paper is to present options to make low-carbon footprint large-scale desalination a reality on arid islands with weak electrical grids. Through these options, the goal is to reconfigure on-grid wind energy/ desalination systems for large- and medium-scale water production. In this context, it is proposed to use lithium- ion batteries for stationary energy storage together with management strategies aimed at avoiding the wind energy/desalination systems having to consume energy from the conventional grid they are connected to. The control strategy is based on ensuring that the power provided by the wind farm and batteries remains in synchrony with the power demand of the desalination plant throughout the system’s useful life. The interannual variation of wind energy is considered when sizing the renewable energy system and processes for its estimation are proposed. The case study is centred on the Canary Archipelago, a region that is especially vulnerable to the impacts of climate change, but which enjoys exceptional characteristics for the exploitation of wind energy. The results obtained show the optimal wind farm and energy storage system capacities of the analysed configurations. The approach presented allows a low-carbon operational footprint. If the control strategy were to be put into practice today, the current grid restrictions and a life cycle assessment of the system carried out in a societal context that continues to be fossil fuel dependent indicate a potential reduction of 77.4% of the footprint. However, the remaining 22.6% could be eliminated in the future when the manufacturing processes of wind turbines, batteries and desalination plants receive the benefits of carbon-neutral societies.
URI: http://hdl.handle.net/10553/128474
ISSN: 0306-2619
DOI: 10.1016/j.apenergy.2023.122564
Fuente: Applied Energy [ISSN 0306-2619], v. 358, 122564, (Marzo 2024)
Colección:Artículos
Adobe PDF (21,15 MB)
Vista completa

Citas SCOPUSTM   

5
actualizado el 17-nov-2024

Citas de WEB OF SCIENCETM
Citations

5
actualizado el 17-nov-2024

Visitas

234
actualizado el 05-oct-2024

Descargas

159
actualizado el 05-oct-2024

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.