Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/121745
Título: | Indwelling catheter patient experiences and the potential usability and acceptance of the T-Control® prototype urinary catheter | Autores/as: | Toledo-Chavarri, A. Bassas-Parga, A. Endrenyi, S. Luque González, Manuel Bezos-Daleske, C. Reyero, V. Serrano-Aguilar, P. Batista-Miranda, J. E. |
Clasificación UNESCO: | 32 Ciencias médicas 3201 Ciencias clínicas 331110 Instrumentos médicos |
Palabras clave: | Bladder Catheters Patient Experience Patient Journey Map T-Control® User-Centred Design |
Fecha de publicación: | 2023 | Publicación seriada: | International Journal of Urological Nursing | Resumen: | The aim of this study was to analyse the experience of users of indwelling bladder catheters and evaluate the anticipated usability of a prototype of the T-Control® urinary catheter (without being inserted) by patients who were able to compare the differences between the T-Control® prototype and other urinary catheters and urinary catheter accessories. A qualitative study was conducted with people who had lived with an indwelling urinary catheter for at least 1 week. Two user-centred design techniques were applied: patient experience trajectory map and Think Aloud, a method where the participants were able to express their previous experiences, expectations and preferences while manipulating the devices. The experiential trajectory was collected based on a semi-structured following interviews. Participants were able to manipulate the new T-Control® and, based on their previous experiences, compare the potential usability of T-control® with Foley-type catheter and its accessories All the participants stated that they had experienced negative emotions concerning bladder catheterisation during the trajectory of use, from the initial prescription and adaptation to the follow-up, and the forced life changes that a permanent catheterisation implies. The most frequent emotions were rejection and sadness. The new T-Control® device could potentially improve the patient experience, as all participants perceived advantages related to the closure system, ease of use, safety and discretion. Participants also noted its closure system as an advantage and highlighted its ease of use, although one-handed operation required some learning. Catheters currently on the market are functional, but some patients do not always have a satisfactory experience. This might negatively affect their quality of life, so there is a wide market opportunity for new devices that improve clinical and psychological care. Based on patient evaluation, the new T-Control® device with a built-in valve could provide benefits for patients. | URI: | http://hdl.handle.net/10553/121745 | ISSN: | 1749-7701 | DOI: | 10.1111/ijun.12362 | Fuente: | International Journal of Urological Nursing [ISSN 1749-7701], (Enero 2023) |
Colección: | Artículos |
Citas SCOPUSTM
2
actualizado el 17-nov-2024
Citas de WEB OF SCIENCETM
Citations
2
actualizado el 17-nov-2024
Visitas
36
actualizado el 23-may-2024
Descargas
64
actualizado el 23-may-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.