Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/121678
Título: | Experimental Research on New Developed Titanium Alloys for Biomedical Applications | Autores/as: | Jiménez Marcos, Cristina Mirza Rosca, Julia Claudia Baltatu, Madalina Simona Vizureanu, Petrica |
Clasificación UNESCO: | 3313 Tecnología e ingeniería mecánicas | Palabras clave: | Corrosion Behavior Mechanical Properties Microstructure Ti20Mo7Zr Ti20Mo7Zr0.5Si, et al. |
Fecha de publicación: | 2022 | Publicación seriada: | Bioengineering | Resumen: | The mechanical properties and electrochemical behavior of two new titanium alloys, Ti20Mo7Zr and Ti20Mo7Zr0.5Si, are investigated in this paper. The alloys have been manufactured by vacuum arc remelting (VAR) technique and studied to determine their microstructure, corrosion behavior, and mechanical properties. Metallographic observations and quantitative microanalysis by optical microscopy, scanning electron microscopy SEM, and energy dispersive X-rays spectroscopy EDX were performed. Data about the three-point bending test and microhardness are presented. For electrochemical properties, three different environments were used: Ringer solution at 25 °C, Ringer solution at 40 °C simulating fever condition, and 3.5% NaCl solution. Metallographic investigation revealed the biphasic and dendritic structure of both samples when the procedures were performed. Electrochemical testing in body simulation fluid, fever conditions, and saline medium showed that the lower the proportion of silicon in the samples, the higher the corrosion resistance. The formation of a titanium oxide layer on the surface of both samples was noticed using quantitative EDX analysis. The three-point bending test for the two samples revealed that the presence of silicon decreases the modulus of elasticity; the surface of the samples displayed soft and hard phases in the microhardness test. Electrochemical impedance spectroscopy (EIS) measurements were carried out at different potentials, and the obtained spectra exhibit a two-time constant system, attesting double-layer passive film on the samples. | URI: | http://hdl.handle.net/10553/121678 | ISSN: | 2306-5354 | DOI: | 10.3390/bioengineering9110686 | Fuente: | Bioengineering [EISSN 2306-5354], v. 9 (11), 686, (Noviembre 2022) |
Colección: | Artículos |
Citas SCOPUSTM
19
actualizado el 17-nov-2024
Citas de WEB OF SCIENCETM
Citations
18
actualizado el 17-nov-2024
Visitas
12
actualizado el 04-nov-2023
Descargas
20
actualizado el 04-nov-2023
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.