Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/119034
Título: | Dynamic Visual Acuity Results in Otolith Electrical Stimulation in Bilateral Vestibular Dysfunction | Autores/as: | Rodríguez Montesdeoca, Isaura Ramos De Miguel, Ángel Falcon Gonzalez, Juan Carlos Borkoski Barreiro, Silvia Benítez-Robaina, Susana Guerra Jimenez, Gloria Pavone, Joana Ramos Macías, Ángel Manuel |
Clasificación UNESCO: | 32 Ciencias médicas 321305 Cirugía de garganta, nariz y oídos |
Palabras clave: | Bilateral Vestibular Disease (Bvd) Dynamic Visual Acuity (Dva) Oscillopsia Severity Questionnaire (Osq) Vestibular Implant Vestibulo-Ocular Reflex (Vor) |
Fecha de publicación: | 2022 | Publicación seriada: | Journal of Clinical Medicine | Resumen: | (1) Background. Patients with bilateral vestibular disease (BVD) experience oscillopsia with a detriment to visual acuity (VA). This VA is driven mainly by the VOR that has two components: rotational and translational. VA can be tested by using dynamic visual acuity (DVA) on a treadmill because both systems are activated. The aim of this study is to compare VA before and after chronic electrical stimulation of the otolith organ. (2) Materials and Method. Five patients suffering from bilateral vestibular dysfunction (BVD), previously implanted with a new vestibular implant prototype, were included in this study with the aim to check VA with and without vestibular implant use (W and W/O) in static, 2 km/h and 4 km/h walking situations. DVAtreadmill was measured on a treadmill with a dynamic illegible E (DIE) test in static and dynamic conditions (while walking on the treadmill at 2 and 4 km/h). The DVA score was registered in a logarithm of the minimum angle of resolution (LogMAR) for each speed. In addition, every patient completed the oscillopsia severity questionnaire (OSQ) and video head impulse test (vHIT) before and after activation of the vestibular implant. (3) Results. The analysis shows a significant difference in OSQ scores and DVA with an improvement in dynamic conditions. Organized corrective saccades during the use of a vestibular implant with no changes in gain were also detected in the video head impulse tests (vHIT). (4) Conclusion. The vestibular implant with otolithic stimulation offers changes in the response of DVA, which makes this paper one of the first to address the possible restoration of it. It is not possible to rule out other contributing factors (presence of covert saccades, somatosensory system, …). More work seems necessary to understand the neurophysiological basis of these findings, but this implant is added as a therapeutic alternative for the improvement of oscillopsia. | URI: | http://hdl.handle.net/10553/119034 | ISSN: | 2077-0383 | DOI: | 10.3390/jcm11195706 | Fuente: | Journal of Clinical Medicine[EISSN 2077-0383],v. 11 (19), (Septiembre 2022) |
Colección: | Artículos |
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.