Please use this identifier to cite or link to this item: http://hdl.handle.net/10553/77424
Title: Técnicas de reconocimiento automático de patrones aplicadas a imágenes hiperespectrales médicas
Authors: Ortega Sarmiento, Samuel 
Director: Marrero Callicó, Gustavo Iván 
Camacho Galán, Rafael 
UNESCO Clasification: 3325 Tecnología de las telecomunicaciones
3314 Tecnología médica
Issue Date: 2016
Project: Hyperspectral Imaging Cancer Detection (Helicoid) (Contrato Nº 618080) 
Abstract: Hyperspectral imaging is an emerging technology for medical diagnosis. Some previous studies have employed this technology for detecting cancer diseases. In this research work, a multidisciplinary team compounds by pathologists and engineers present a proof of concept of using hyperspectral imaging analysis in order to detect human brain tumour tissue inside pathological slides. The samples were acquired from four different patient diagnosed with brain cancer, specifically with high-grade gliomas. The hyperspectral capture system consists on a hyperspectral camera coupled with a microscope. This system works in the VNIR spectral range (from 400 nm to 1000 nm) with a spectral resolution of 3 nm. The images where then processed in order to remove the effect caused by the acquisition system. Later, and based on the diagnostic provided by pathologist, a spectral dataset containing only labelled spectra from normal and tumour tissue was created. The data were then processed using three different supervised learning algorithms: Support Vector Machines, Artificial Neural Networks and Random Forests. The capabilities of discriminating between normal and tumour issue have been evaluated in three different scenarios, where the inter-patient variability of data was or not taken into account. The results achieved in this research study are promising, showing that it is possible to distinguish between normal and tumour tissue exclusively attending to the spectral signature of tissue.
Faculty: Escuela de Ingeniería de Telecomunicación y Electrónica
Institute: IU de Microelectrónica Aplicada
Degree: Máster Universitario en Tecnologías de Telecomunicación
URI: http://hdl.handle.net/10553/77424
Appears in Collections:Trabajo final de máster
Thumbnail
Adobe PDF (4,23 MB)
Thumbnail
Adobe PDF (916,9 kB)
Thumbnail
Adobe PDF (412,08 kB)

En el caso de que no encuentre el documento puede ser debido a que el centro o las/os autoras/es no autorizan su publicación. Si tiene verdadero interés en el contenido del mismo, puede dirigirse al director/a o directores/as del trabajo cuyos datos encontrará más arriba.

Show full item record

Google ScholarTM

Check


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.