dc.contributor.authorVilla, E.en_US
dc.contributor.authorArteaga-Marrero, N.en_US
dc.contributor.authorLeón, G.en_US
dc.contributor.authorHerrán, L. F.en_US
dc.contributor.authorMateos, I.en_US
dc.contributor.authorRuiz-Alzola, J.en_US
dc.date.accessioned2021-01-27T10:03:00Z-
dc.date.available2021-01-27T10:03:00Z-
dc.date.issued2021en_US
dc.identifier.issn1434-8411en_US
dc.identifier.otherScopus-
dc.identifier.urihttp://hdl.handle.net/10553/77347-
dc.description.abstractA pseudo-correlation type radiometer based on astrophysical instrumentation is for biomedical applications. The working frequency band is centred at 3.5 GHz. The prototype performance and functionality are assessed. The theoretical analysis of the receiver topology is described, as well as the subsystems employed in its configuration, such as a customized on-body antenna and microwave circuitry based on off-the-shelf devices. Experimental characterization of the individual subsystems and preliminary measurements of the radiometer prototype are presented. Furthermore, customized phantoms, based on polyvinyl alcohol cryogel, are employed for the characterization of the on-body antenna, as well as the radiometer.en_US
dc.languageengen_US
dc.relation.ispartofAEU - International Journal of Electronics and Communicationsen_US
dc.sourceAEU - International Journal of Electronics and Communications [ISSN 1434-8411], v. 130, 153558, (Febrero 2021)en_US
dc.subject3314 Tecnología médicaen_US
dc.subject.otherBiomedical Applicationsen_US
dc.subject.otherCalibrationen_US
dc.subject.otherPhantomsen_US
dc.subject.otherPseudo-Correlation Radiometeren_US
dc.titleA 3.5-GHz pseudo-correlation type radiometer for biomedical applicationsen_US
dc.typeinfo:eu-repo/semantics/Articleen_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.aeue.2020.153558en_US
dc.identifier.scopus85099259751-
dc.contributor.authorscopusid26325126700-
dc.contributor.authorscopusid14038607600-
dc.contributor.authorscopusid25638615000-
dc.contributor.authorscopusid11141407800-
dc.contributor.authorscopusid36195777800-
dc.contributor.authorscopusid56614041800-
dc.identifier.eissn1618-0399-
dc.relation.volume130en_US
dc.investigacionIngeniería y Arquitecturaen_US
dc.type2Artículoen_US
dc.utils.revisionen_US
dc.date.coverdateFebrero 2021en_US
dc.identifier.ulpgcen_US
dc.contributor.buulpgcBU-TELen_US
dc.description.sjr0,719
dc.description.jcr3,169
dc.description.sjrqQ2
dc.description.jcrqQ2
item.fulltextSin texto completo-
item.grantfulltextnone-
crisitem.author.deptGIR IUIBS: Patología y Tecnología médica-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Señales y Comunicaciones-
crisitem.author.orcid0000-0002-3545-2328-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.fullNameRuiz Alzola, Juan Bautista-
Appears in Collections:Artículos
Show simple item record

SCOPUSTM   
Citations

8
checked on Mar 2, 2025

WEB OF SCIENCETM
Citations

9
checked on Mar 2, 2025

Page view(s)

200
checked on Nov 1, 2024

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.