Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/76953
DC Field | Value | Language |
---|---|---|
dc.contributor.author | López-Silva, S. M. | en_US |
dc.contributor.author | Dotor, M. L. | en_US |
dc.contributor.author | Silveira, J. P. | en_US |
dc.contributor.author | Giannetti, Romano | en_US |
dc.contributor.author | Golmayo, D. | en_US |
dc.contributor.author | Martín Escudero, Pilar | en_US |
dc.contributor.author | Miguel-Tobal, F. | en_US |
dc.contributor.author | Bilbao, A. | en_US |
dc.contributor.author | Álvarez-Sala, J. L. | en_US |
dc.contributor.author | Herrera, L. | en_US |
dc.date.accessioned | 2020-12-23T10:32:47Z | - |
dc.date.available | 2020-12-23T10:32:47Z | - |
dc.date.issued | 2004 | en_US |
dc.identifier.isbn | 0-7803-8248-X | en_US |
dc.identifier.issn | 1091-5281 | en_US |
dc.identifier.other | Scopus | - |
dc.identifier.uri | http://hdl.handle.net/10553/76953 | - |
dc.description.abstract | Photoplethysmography and pulse oximetry are widely used techniques for noninvasive monitoring of heart rate and peripheral oxygen saturation. Over the last years we have been working onto the application of near infrared range wavelengths to replace those of the classical pulse oximeters. The development of laser diodes based sensors, processing algorithms, a calibration procedure, and the comparison with a commercial pulse oximeter, have been followed by a set of experimental studies. The results exposed here demonstrate the applicability of transmittance photoplethysmography and pulse oximetry using laser diodes emitting at specific wavelengths for a wide range of situations. | en_US |
dc.language | eng | en_US |
dc.publisher | Institute of Electrical and Electronics Engineers (IEEE) | en_US |
dc.relation.ispartof | Conference proceedings - IEEE Instrumentation/Measurement Technology Conference | en_US |
dc.source | Conference Record - IEEE Instrumentation and Measurement Technology Conference [ISSN 1091-5281], v. 1, p. 718-723, 2004 | en_US |
dc.subject | 3307 Tecnología electrónica | en_US |
dc.subject | 331110 Instrumentos médicos | en_US |
dc.subject.other | Laser Diodes | en_US |
dc.subject.other | Optical Sensor | en_US |
dc.subject.other | Photoplethysmography | en_US |
dc.subject.other | Pulse Oximetry | en_US |
dc.title | Transmittance photoplethysmography and pulse oximetry with near infrared laser diodes | en_US |
dc.type | info:eu-repo/semantics/conferenceObject | en_US |
dc.type | ConferenceObject | en_US |
dc.relation.conference | Proceedings of the 21st IEEE Instrumentation and Measurement Technology Conference, IMTC/04 | en_US |
dc.identifier.doi | 10.1109/IMTC.2004.1351147 | en_US |
dc.identifier.scopus | 4644306231 | - |
dc.contributor.authorscopusid | 6603011574 | - |
dc.contributor.authorscopusid | 6701813964 | - |
dc.contributor.authorscopusid | 22968877900 | - |
dc.contributor.authorscopusid | 7004521221 | - |
dc.contributor.authorscopusid | 6701814842 | - |
dc.contributor.authorscopusid | 7406037855 | - |
dc.contributor.authorscopusid | 6504201088 | - |
dc.contributor.authorscopusid | 55316874400 | - |
dc.contributor.authorscopusid | 7005103750 | - |
dc.contributor.authorscopusid | 36169786000 | - |
dc.description.lastpage | 723 | en_US |
dc.description.firstpage | 718 | en_US |
dc.relation.volume | 1 | en_US |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Actas de congresos | en_US |
dc.utils.revision | Sí | en_US |
dc.date.coverdate | Octubre 2004 | en_US |
dc.identifier.conferenceid | events121344 | - |
dc.identifier.ulpgc | Sí | en_US |
item.grantfulltext | open | - |
item.fulltext | Con texto completo | - |
crisitem.event.eventsstartdate | 18-05-2004 | - |
crisitem.event.eventsenddate | 20-05-2004 | - |
Appears in Collections: | Actas de congresos |
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.