Please use this identifier to cite or link to this item:
https://accedacris.ulpgc.es/handle/10553/76059
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Schaap, Michiel | en_US |
dc.contributor.author | Metz, Coert T. | en_US |
dc.contributor.author | van Walsum, Theo | en_US |
dc.contributor.author | van der Giessen, Alina G. | en_US |
dc.contributor.author | Weustink, Annick C. | en_US |
dc.contributor.author | Mollet, Nico R. | en_US |
dc.contributor.author | Bauer, Christian | en_US |
dc.contributor.author | Bogunovic, Hrvoje | en_US |
dc.contributor.author | Castro, Carlos | en_US |
dc.contributor.author | Deng, Xiang | en_US |
dc.contributor.author | Dikici, Engin | en_US |
dc.contributor.author | O'Donnell, Thomas | en_US |
dc.contributor.author | Frenay, Michel | en_US |
dc.contributor.author | Friman, Ola | en_US |
dc.contributor.author | Hernandez Hoyos, Marcela | en_US |
dc.contributor.author | Kitslaar, Pieter H. | en_US |
dc.contributor.author | Krissian, Karl | en_US |
dc.contributor.author | Kuehnel, Caroline | en_US |
dc.contributor.author | Luengo-Oroz, Miguel A. | en_US |
dc.contributor.author | Orkisz, Maciej | en_US |
dc.contributor.author | Smedby, Orjan | en_US |
dc.contributor.author | Styner, Martin | en_US |
dc.contributor.author | Szymczak, Andrzej | en_US |
dc.contributor.author | Tek, Hueseyin | en_US |
dc.contributor.author | Wang, Chunliang | en_US |
dc.contributor.author | Warfield, Simon K. | en_US |
dc.contributor.author | Zambal, Sebastian | en_US |
dc.contributor.author | Zhang, Yong | en_US |
dc.contributor.author | Krestin, Gabriel P. | en_US |
dc.contributor.author | Niessen, Wiro J. | en_US |
dc.date.accessioned | 2020-11-26T12:33:01Z | - |
dc.date.available | 2020-11-26T12:33:01Z | - |
dc.date.issued | 2009 | en_US |
dc.identifier.issn | 1361-8415 | en_US |
dc.identifier.other | WoS | - |
dc.identifier.uri | https://accedacris.ulpgc.es/handle/10553/76059 | - |
dc.description.abstract | Efficiently obtaining a reliable coronary artery centerline from computed tomography angiography data is relevant in clinical practice. Whereas numerous methods have been presented for this purpose, up to now no standardized evaluation methodology has been published to reliably evaluate and compare the performance of the existing or newly developed coronary artery centerline extraction algorithms. This paper describes a standardized evaluation methodology and reference database for the quantitative evaluation of coronary artery centerline extraction algorithms. The contribution of this work is fourfold: (1) a method is described to create a consensus centerline with multiple observers, (2) well-defined measures are presented for the evaluation of coronary artery centerline extraction algorithms, (3) a database containing 32 cardiac CTA datasets with corresponding reference standard is described and made available. and (4) 13 coronary artery centerline extraction algorithms, implemented by different research groups, are quantitatively evaluated and compared. The presented evaluation framework is made available to the medical imaging community for benchmarking existing or newly developed coronary centerline extraction algorithms. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Medical Image Analysis | en_US |
dc.source | Medical Image Analysis [ISSN 1361-8415], v. 13 (5), p. 701-714, (Octubre 2009) | en_US |
dc.subject | 32 Ciencias médicas | en_US |
dc.subject.other | Computed-Tomography | en_US |
dc.subject.other | Vessel Segmentation | en_US |
dc.subject.other | Radiation-Exposure | en_US |
dc.subject.other | Angiography | en_US |
dc.subject.other | Tree | en_US |
dc.subject.other | Reconstruction | en_US |
dc.subject.other | Accuracy | en_US |
dc.subject.other | Tracking | en_US |
dc.subject.other | Images | en_US |
dc.subject.other | Standardized Evaluation | en_US |
dc.subject.other | Centerline Extraction | en_US |
dc.subject.other | Tracking | en_US |
dc.subject.other | Coronaries | en_US |
dc.subject.other | Computed Tomography | en_US |
dc.title | Standardized evaluation methodology and reference database for evaluating coronary artery centerline extraction algorithms | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1016/j.media.2009.06.003 | en_US |
dc.identifier.scopus | 68949196294 | - |
dc.identifier.isi | 000270264200002 | - |
dc.contributor.authorscopusid | 23009718200 | - |
dc.contributor.authorscopusid | 20735327800 | - |
dc.contributor.authorscopusid | 6603247641 | - |
dc.contributor.authorscopusid | 23010839200 | - |
dc.contributor.authorscopusid | 14020805000 | - |
dc.contributor.authorscopusid | 6701617379 | - |
dc.contributor.authorscopusid | 57146280000 | - |
dc.contributor.authorscopusid | 9269313300 | - |
dc.contributor.authorscopusid | 36717433200 | - |
dc.contributor.authorscopusid | 35308666900 | - |
dc.contributor.authorscopusid | 57190133900 | - |
dc.contributor.authorscopusid | 7103394380 | - |
dc.contributor.authorscopusid | 57197610529 | - |
dc.contributor.authorscopusid | 8426861400 | - |
dc.contributor.authorscopusid | 13104224200 | - |
dc.contributor.authorscopusid | 24343922100 | - |
dc.contributor.authorscopusid | 6602218913 | - |
dc.contributor.authorscopusid | 24332085700 | - |
dc.contributor.authorscopusid | 19639024000 | - |
dc.contributor.authorscopusid | 6603713173 | - |
dc.contributor.authorscopusid | 7003983823 | - |
dc.contributor.authorscopusid | 6701492552 | - |
dc.contributor.authorscopusid | 7004386216 | - |
dc.contributor.authorscopusid | 6603546036 | - |
dc.contributor.authorscopusid | 23399034500 | - |
dc.contributor.authorscopusid | 7005171959 | - |
dc.contributor.authorscopusid | 15043480800 | - |
dc.contributor.authorscopusid | 7601314112 | - |
dc.contributor.authorscopusid | 7007072461 | - |
dc.contributor.authorscopusid | 7006660813 | - |
dc.identifier.eissn | 1361-8423 | - |
dc.description.lastpage | 714 | en_US |
dc.identifier.issue | 5 | - |
dc.description.firstpage | 701 | en_US |
dc.relation.volume | 13 | en_US |
dc.investigacion | Ciencias de la Salud | en_US |
dc.type2 | Artículo | en_US |
dc.contributor.daisngid | 875323 | - |
dc.contributor.daisngid | 466747 | - |
dc.contributor.daisngid | 279430 | - |
dc.contributor.daisngid | 1808313 | - |
dc.contributor.daisngid | 262405 | - |
dc.contributor.daisngid | 103362 | - |
dc.contributor.daisngid | 1223124 | - |
dc.contributor.daisngid | 764891 | - |
dc.contributor.daisngid | 5942138 | - |
dc.contributor.daisngid | 30913564 | - |
dc.contributor.daisngid | 5594199 | - |
dc.contributor.daisngid | 31484152 | - |
dc.contributor.daisngid | 7498227 | - |
dc.contributor.daisngid | 874524 | - |
dc.contributor.daisngid | 7293811 | - |
dc.contributor.daisngid | 516073 | - |
dc.contributor.daisngid | 1202623 | - |
dc.contributor.daisngid | 7171932 | - |
dc.contributor.daisngid | 760236 | - |
dc.contributor.daisngid | 602775 | - |
dc.contributor.daisngid | 226916 | - |
dc.contributor.daisngid | 13703058 | - |
dc.contributor.daisngid | 1165575 | - |
dc.contributor.daisngid | 3847546 | - |
dc.contributor.daisngid | 755408 | - |
dc.contributor.daisngid | 38669 | - |
dc.contributor.daisngid | 4248208 | - |
dc.contributor.daisngid | 11669401 | - |
dc.contributor.daisngid | 21406 | - |
dc.contributor.daisngid | 19934 | - |
dc.description.numberofpages | 14 | en_US |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:Schaap, M | - |
dc.contributor.wosstandard | WOS:Metz, CT | - |
dc.contributor.wosstandard | WOS:van Walsum, T | - |
dc.contributor.wosstandard | WOS:van der Giessen, AG | - |
dc.contributor.wosstandard | WOS:Weustink, AC | - |
dc.contributor.wosstandard | WOS:Mollet, NR | - |
dc.contributor.wosstandard | WOS:Bauer, C | - |
dc.contributor.wosstandard | WOS:Bogunovic, H | - |
dc.contributor.wosstandard | WOS:Castro, C | - |
dc.contributor.wosstandard | WOS:Deng, X | - |
dc.contributor.wosstandard | WOS:Dikici, E | - |
dc.contributor.wosstandard | WOS:O'Donnell, T | - |
dc.contributor.wosstandard | WOS:Frenay, M | - |
dc.contributor.wosstandard | WOS:Friman, O | - |
dc.contributor.wosstandard | WOS:Hoyos, MH | - |
dc.contributor.wosstandard | WOS:Kitslaar, PH | - |
dc.contributor.wosstandard | WOS:Krissian, K | - |
dc.contributor.wosstandard | WOS:Kuhnel, C | - |
dc.contributor.wosstandard | WOS:Luengo-Oroz, MA | - |
dc.contributor.wosstandard | WOS:Orkisz, M | - |
dc.contributor.wosstandard | WOS:Smedby, O | - |
dc.contributor.wosstandard | WOS:Styner, M | - |
dc.contributor.wosstandard | WOS:Szymczak, A | - |
dc.contributor.wosstandard | WOS:Tek, H | - |
dc.contributor.wosstandard | WOS:Wang, CL | - |
dc.contributor.wosstandard | WOS:Warfield, SK | - |
dc.contributor.wosstandard | WOS:Zambal, S | - |
dc.contributor.wosstandard | WOS:Zhang, Y | - |
dc.contributor.wosstandard | WOS:Krestin, GP | - |
dc.contributor.wosstandard | WOS:Niessen, WJ | - |
dc.date.coverdate | Enero 2009 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-MED | en_US |
dc.description.jcr | 3,093 | |
dc.description.jcrq | Q1 | |
dc.description.scie | SCIE | |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
Appears in Collections: | Artículos |
SCOPUSTM
Citations
303
checked on Mar 30, 2025
WEB OF SCIENCETM
Citations
255
checked on Mar 30, 2025
Page view(s)
79
checked on Mar 15, 2025
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.