Please use this identifier to cite or link to this item: http://hdl.handle.net/10553/75924
Title: A new model of abdominal aortic aneurysm with gastric serosa patch: Surgical technique and short-term evaluation
Authors: Uson-Gargallo, J
Crisostomo, V
Loscertales, B
Sun, F
Sanchez-Margallo, FM
Martin-Cancho, MF
Maynar Moliner, Manuel 
UNESCO Clasification: 32 Ciencias médicas
321301 Cirugía abdominal
Keywords: Animal-Model
Thrombus
Rupture
Grafts
Repair, et al
Issue Date: 2006
Journal: Journal of Investigative Surgery 
Abstract: The purpose of this work was to develop an abdominal aortic aneurysm (AAA) model that resembles human aneurysms with potential for further growth, patent collateral vessels, and a predictable tendency to rupture, and that can be used in the development of new endoprostheses and implant training. An infrarenal AAA model was created in five domestic swine using an autologous gastric serosal patch. Pre- and postsurgical digital substraction aortograms (DSA) were obtained to document the appearance and dimensions of the aneurysm. Animals were followed up with DSA and ultrasonography on days 7, 14, 30, 45, 60, and 90 after model creation. Aneurysmal diameters were measured with both techniques in all examinations. On day 90, animals were euthanized, target arteries were harvested, and pathological evaluation was performed. The nonparametric Wilcoxon test was used to assess any differences in measured diameters. All the animals survived the surgical procedure. The aneurysmal diameters increased from 8.14 +/- 2.15 to 13.28 +/- 1.18 mm immediately after surgery (p<.05), but no subsequent significant growth of the aneurysmal sac was seen during follow-up. In this experimental setting, measurements obtained with DSA were slightly larger than those obtained with ultrasound. Two animals died of AAA rupture on days 6 and 10 (40% rupture rate). Pathological examination showed lack of elastic laminae and increased collagen content in the aortic patch. Thus, model showed a tendency to rupture, but no significant potential for further aneurysmal growth. It might be useful for training in endovascular therapies, but its usefulness for preclinical endovascular device testing is limited by its lack of growth potential.
URI: http://hdl.handle.net/10553/75924
ISSN: 0894-1939
DOI: 10.1080/08941930600569415
Source: Journal Of Investigative Surgery [ISSN 0894-1939], v. 19 (2), p. 97-104, (Marzo-Abril 2006)
Appears in Collections:Artículos
Show full item record

SCOPUSTM   
Citations

11
checked on Nov 17, 2024

WEB OF SCIENCETM
Citations

9
checked on Nov 17, 2024

Page view(s)

125
checked on Jul 20, 2024

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.