Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/75590
Título: Development and validation of a computer-aided diagnostic tool to screen for age-related macular degeneration by optical coherence tomography
Autores/as: Serrano-Aguilar, P.
Abreu, R.
Anton-Canalis, L.
Guerra-Artal, C. 
Ramallo-Farina, Y.
Gomez-Ulla, F.
Nadal, J.
Clasificación UNESCO: 220990 Tratamiento digital. Imágenes
1203 Ciencia de los ordenadores
Palabras clave: Automated detection
Maculopathy
Fecha de publicación: 2012
Publicación seriada: British journal of ophthalmology 
Resumen: Background: To develop and assess the technical validity of new computer-aided diagnostic software (CAD) for automated analyses of optical coherence tomography (OCT) images for the purpose of screening for neovascular age-related macular degeneration.Methods: Artificial visual techniques were used to develop the CAD in two steps: normalisation and feature vector extraction from OCT images; and training and classification by means of decision trees. Technical validation was performed by a retrospective study design based on OCT images randomly extracted from clinical charts. Images were classified as normal or abnormal to serve for screening purposes. Sensitivity, specificity, positive predictive values and negative predictive values were obtained.Results: The CAD was able to quantify image information by working in the perceptually uniform hue-saturation-value colour space. Particle swarm optimisation with Haar-like features is suitable to reveal structural features in normal and abnormal OCT images. Decision trees were useful to characterise normal and abnormal images using feature vectors obtained from descriptive statistics of detected structures. The sensitivity of the CAD was 96% and the specificity 92%.Conclusions This new CAD for automated analysis of OCT images offers adequate sensitivity and specificity to distinguish normal OCT images from those showing potential neovascular age-related macular degeneration. These results will enable its clinical validation and a subsequent cost-effectiveness assessment to be made before recommendations are made for population-screening purposes.
URI: http://hdl.handle.net/10553/75590
ISSN: 0007-1161
DOI: 10.1136/bjophthalmol-2011-300660
Fuente: British Journal Of Ophthalmology [ISSN 0007-1161], v. 96 (4), p. 503-507, (Abril 2012)
Colección:Artículos
Vista completa

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.