Please use this identifier to cite or link to this item: http://hdl.handle.net/10553/74511
DC FieldValueLanguage
dc.contributor.authorPiqueras-Sanchiz, Franciscoen_US
dc.contributor.authorMartín Rodríguez, Saúlen_US
dc.contributor.authorPareja-Blanco, Fernandoen_US
dc.contributor.authorBaraja-Vegas, Luisen_US
dc.contributor.authorBlázquez-Fernández, Jorgeen_US
dc.contributor.authorBautista, Iker J.en_US
dc.contributor.authorGarcía-García, Óscaren_US
dc.date.accessioned2020-09-21T11:28:04Z-
dc.date.available2020-09-21T11:28:04Z-
dc.date.issued2020en_US
dc.identifier.otherScopus-
dc.identifier.urihttp://hdl.handle.net/10553/74511-
dc.description.abstractThe aim was to determine the effects of changing pulse duration and electrode size on muscle contractile properties. Thirty-six healthy young male participated in the study (age 24.8 ± 5.8 years; height 178.2 ± 0.6 cm; body mass 71.8 ± 7.3 kg; self-reported weekly moderate intensity activity 3.5 ± 1.2 h·week−1). Tensiomyography was used to assess rectus femoris (RF) and vastus medialis (VM) muscles neuromuscular properties of the dominant leg according to the electrode size (3.2–5 cm) and the stimulus length (0.2, 0.5, and 1 ms). Maximal radial displacement (Dm); Contraction time (Tc); Delay time (Td); Sustained time (Ts) and Half relaxation time (Tr) were measured. Relative and absolute reliability was quantified. To analyze the effects of the electrode and the stimulus length, a repeated-measures analysis of variance was used. Dm and Tc parameters showed for both muscles an excellent relative (0.95–0.99) and absolute reliability (1.6–4.2%). However, Ts and Tr showed low values of absolute reliability (4.4–40.9%). The duration of the stimulus length applied to the RF and VM and electrode size significantly influences muscle’s contractile properties (p < 0.05; η2 p = 0.09–0.60). The Dm increases substantially as the duration of the stimulus increases and with the use of the larger electrode in both muscles. However, Tc and Td are less affected by both conditions and not entirely clear. Practically, our study suggests that a stimulus pulse duration of 1 ms together with a 5 × 5 cm electrode is necessary to reach a reliable and reproducible assessment of both RF and VM muscles contractile properties.en_US
dc.languageengen_US
dc.relation.ispartofScientific Reportsen_US
dc.sourceScientific Reports[EISSN 2045-2322],v. 10 (1), (Diciembre 2020)en_US
dc.subject241106 Fisiología del ejercicioen_US
dc.subject.othermuscleen_US
dc.subject.otherelectrodesen_US
dc.subject.otherpulseen_US
dc.subject.otherTensiomyographyen_US
dc.titleMechanomyographic Measures of Muscle Contractile Properties are Influenced by Electrode Size and Stimulation Pulse Durationen_US
dc.typeinfo:eu-repo/semantics/Articleen_US
dc.typeArticleen_US
dc.identifier.doi10.1038/s41598-020-65111-zen_US
dc.identifier.scopus85084913307-
dc.contributor.authorscopusid57194395450-
dc.contributor.authorscopusid56335855800-
dc.contributor.authorscopusid56109213000-
dc.contributor.authorscopusid57215350789-
dc.contributor.authorscopusid57216836376-
dc.contributor.authorscopusid6506562367-
dc.contributor.authorscopusid55315989200-
dc.identifier.eissn2045-2322-
dc.identifier.issue1-
dc.relation.volume10en_US
dc.investigacionCiencias de la Saluden_US
dc.type2Artículoen_US
dc.utils.revisionen_US
dc.date.coverdateDiciembre 2020en_US
dc.identifier.ulpgces
dc.description.sjr1,24
dc.description.jcr4,379
dc.description.sjrqQ1
dc.description.jcrqQ1
dc.description.scieSCIE
item.grantfulltextnone-
item.fulltextSin texto completo-
crisitem.author.deptGIR IUIBS: Rendimiento humano, ejercicio físico y salud-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.orcid0000-0003-2423-5309-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.fullNameMartín Rodríguez, Saúl-
Appears in Collections:Artículos
Show simple item record

SCOPUSTM   
Citations

17
checked on Oct 13, 2024

WEB OF SCIENCETM
Citations

16
checked on Oct 13, 2024

Page view(s)

90
checked on Feb 17, 2024

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.