Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/74385
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Santana Sosa, Graciela | en_US |
dc.contributor.author | Santana Abril, Judith | en_US |
dc.contributor.author | Sosa González, Carlos Javier | en_US |
dc.contributor.author | Montiel-Nelson, Juan A. | en_US |
dc.contributor.author | Bautista, Tomas | en_US |
dc.date.accessioned | 2020-09-15T08:22:40Z | - |
dc.date.available | 2020-09-15T08:22:40Z | - |
dc.date.issued | 2020 | en_US |
dc.identifier.issn | 1424-8220 | en_US |
dc.identifier.other | Scopus | - |
dc.identifier.uri | http://hdl.handle.net/10553/74385 | - |
dc.description.abstract | In this paper, we present the design of a practical underwater sensor network for offshore fish farm cages. An overview of the current structure of an offshore fish farm, applied sensor network solutions, and their weaknesses are given. A mixed wireless–wired approach is proposed to mitigate the problem of wire breakage in underwater wired sensor networks. The approach is based on the serial arrangement of identical sections with wired and wireless interconnections areas. Wireless section alleviates underwater maintenance operations when cages are damaged. The analytical model of the proposed solution is studied in terms of maximum power transfer efficiency and the general formulas of the current in their transmitting antennas and sensor nodes are provided. Subsequently, based on simulations, the effects of parasitic resistance across the network are evaluated. A practical underwater sensor network to reach the 30 m depth with sensor nodes distanced 6 m is used to determine the proposal compliance with the ISO 11784/11785 HDX standard in its normal operation. Taking into account the cable breakage scenario, the results from experiments demonstrate the robustness of the proposed approach to keep running the sensor nodes that are located before the short circuit. Sensor node run time is reduced only 4.07% at most using standard values when a cable breakage occurs at the second deepest section. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Sensors (Switzerland) | en_US |
dc.source | Sensors (Switzerland) [ISSN 1424-8220], v. 20 (16), 4459, (Agosto 2020) | en_US |
dc.subject | 3307 Tecnología electrónica | en_US |
dc.subject.other | Offshore Fish Farm | en_US |
dc.subject.other | Precision Aquaculture | en_US |
dc.subject.other | Underwater Sensor Network (USN) | en_US |
dc.subject.other | Wireless Power Transfer (WPT) | en_US |
dc.subject.other | Wireless Sensor Network (WSN) | en_US |
dc.title | Design of a practical underwater sensor network for offshore fish farm cages | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.3390/s20164459 | en_US |
dc.identifier.scopus | 85089350214 | - |
dc.identifier.scopus | 85089408399 | - |
dc.contributor.authorscopusid | 57207114356 | - |
dc.contributor.authorscopusid | 57207112300 | - |
dc.contributor.authorscopusid | 7006310063 | - |
dc.contributor.authorscopusid | 6603626866 | - |
dc.contributor.authorscopusid | 6603190709 | - |
dc.contributor.authorscopusid | 57207114029 | - |
dc.contributor.authorscopusid | 57197715790 | - |
dc.identifier.eissn | 1424-8220 | - |
dc.description.lastpage | 25 | en_US |
dc.identifier.issue | 16 | - |
dc.description.firstpage | 1 | en_US |
dc.relation.volume | 20 | en_US |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Artículo | en_US |
dc.description.notas | This article belongs to the Special Issue Underwater Sensor Networks | en_US |
dc.utils.revision | Sí | en_US |
dc.date.coverdate | Agosto 2020 | en_US |
dc.identifier.ulpgc | Sí | es |
dc.description.sjr | 0,636 | |
dc.description.jcr | 3,576 | |
dc.description.sjrq | Q2 | |
dc.description.jcrq | Q2 | |
dc.description.scie | SCIE | |
item.grantfulltext | open | - |
item.fulltext | Con texto completo | - |
crisitem.author.dept | GIR IUMA: Instrumentación avanzada | - |
crisitem.author.dept | IU de Microelectrónica Aplicada | - |
crisitem.author.dept | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.dept | GIR IUMA: Instrumentación avanzada | - |
crisitem.author.dept | IU de Microelectrónica Aplicada | - |
crisitem.author.dept | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.dept | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.orcid | 0000-0003-1838-3073 | - |
crisitem.author.orcid | 0000-0003-4323-8097 | - |
crisitem.author.orcid | 0000-0002-5368-3680 | - |
crisitem.author.parentorg | IU de Microelectrónica Aplicada | - |
crisitem.author.parentorg | IU de Microelectrónica Aplicada | - |
crisitem.author.fullName | Santana Sosa, Graciela | - |
crisitem.author.fullName | Santana Abril, Judith | - |
crisitem.author.fullName | Sosa González, Carlos Javier | - |
crisitem.author.fullName | Montiel Nelson, Juan Antonio | - |
crisitem.author.fullName | Bautista Delgado, Tomás | - |
Appears in Collections: | Artículos |
SCOPUSTM
Citations
16
checked on Nov 24, 2024
WEB OF SCIENCETM
Citations
16
checked on Nov 24, 2024
Page view(s)
88
checked on May 23, 2024
Download(s)
120
checked on May 23, 2024
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.