Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/73954
Campo DC Valoridioma
dc.contributor.authorPan, Manuelen_US
dc.contributor.authorRomero, Miguelen_US
dc.contributor.authorOjeda, Soledaden_US
dc.contributor.authorSuarez de Lezo, Javieren_US
dc.contributor.authorSegura, Joseen_US
dc.contributor.authorMazuelos, Franciscoen_US
dc.contributor.authorMartin, Pedroen_US
dc.contributor.authorMedina, Alfonsoen_US
dc.contributor.authorSuarez de Lezo, Joseen_US
dc.date.accessioned2020-08-05T08:47:08Z-
dc.date.available2020-08-05T08:47:08Z-
dc.date.issued2015en_US
dc.identifier.issn0002-9149en_US
dc.identifier.otherWoS-
dc.identifier.urihttp://hdl.handle.net/10553/73954-
dc.description.abstractThe possibility of strut fractures after bioresorbable vascular scaffold (BVS) treatment is a new problem associated with the use of this novel technology. There is little in vivo information regarding the effects of lateral dilation on BVS. The present study aimed to evaluate the effects of lateral balloon dilation after bioresorbable vascular scaffold implantation in the treatment of bifurcation lesions. From January 2012 to February 2015, 49 patients with bifurcation lesions who had been treated with BVS required balloon dilation of the side branch (SB). Optical coherence tomographic studies were performed in each of these patients. In 3 patients (6%), the optical coherence tomographic results met the criteria for rupture. Prolonged inflation using a noncompliant balloon with a diameter within the expansion limits of the device resolved the complication in all patients. The clinical course was favorable in all patients, and there were no inhospital deaths or myocardial infarctions. At 14 +/- 8 months of follow-up, 2 patients with integrity of the BVS presented target lesion revascularization (4%). Another patient (2%) suffered a probable stent thrombosis 11 months after the procedure (myocardial infarction and death at home). The patients with the BVS rupture at the index procedure had a favorable clinical outcome, and the 6-month computed tomographic scan revealed maintenance of the initial good results. In conclusion, minor BVS rupture after 2.5-mm lateral balloon dilation may occur but is infrequent (6%). Prolonged balloon inflation of the main vessel may partially restore the geometry of the BVS.en_US
dc.languageengen_US
dc.relation.ispartofThe American journal of cardiologyen_US
dc.sourceThe American journal of cardiology [ISSN 0002-9149], v. 116 (7), p. 1045-1049, (Octubre 2015)en_US
dc.subject320501 Cardiologíaen_US
dc.subject.otherMyocardial-Infarctionen_US
dc.subject.otherClinical-Evaluationen_US
dc.subject.otherImaging Outcomesen_US
dc.subject.otherStenten_US
dc.subject.otherImplantationen_US
dc.subject.otherLesionsen_US
dc.titleFracture of bioresorbable vascular scaffold after side-branch balloon dilation in bifurcation coronary narrowingsen_US
dc.typeinfo:eu-repo/semantics/Articleen_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.amjcard.2015.07.015en_US
dc.identifier.scopus84941176057-
dc.identifier.isi000362382400009-
dc.contributor.authorscopusid7202544866-
dc.contributor.authorscopusid7202430759-
dc.contributor.authorscopusid8654250900-
dc.contributor.authorscopusid16067353500-
dc.contributor.authorscopusid55415591100-
dc.contributor.authorscopusid24450657100-
dc.contributor.authorscopusid7406037925-
dc.contributor.authorscopusid7202723590-
dc.contributor.authorscopusid7006785516-
dc.identifier.eissn1879-1913-
dc.description.lastpage1049en_US
dc.identifier.issue7-
dc.description.firstpage1045en_US
dc.relation.volume116en_US
dc.investigacionCiencias de la Saluden_US
dc.type2Artículoen_US
dc.contributor.daisngid77557-
dc.contributor.daisngid156230-
dc.contributor.daisngid343824-
dc.contributor.daisngid67522-
dc.contributor.daisngid1825688-
dc.contributor.daisngid452208-
dc.contributor.daisngid1673863-
dc.contributor.daisngid74576-
dc.contributor.daisngid476437-
dc.description.numberofpages5en_US
dc.utils.revisionen_US
dc.contributor.wosstandardWOS:Pan, M-
dc.contributor.wosstandardWOS:Romero, M-
dc.contributor.wosstandardWOS:Ojeda, S-
dc.contributor.wosstandardWOS:de Lezo, JS-
dc.contributor.wosstandardWOS:Segura, J-
dc.contributor.wosstandardWOS:Mazuelos, F-
dc.contributor.wosstandardWOS:Martin, P-
dc.contributor.wosstandardWOS:Medina, A-
dc.contributor.wosstandardWOS:de Lezo, JS-
dc.date.coverdateOctubre 2015en_US
dc.identifier.ulpgces
dc.description.sjr2,065
dc.description.jcr3,154
dc.description.sjrqQ1
dc.description.jcrqQ2
dc.description.scieSCIE
item.grantfulltextnone-
item.fulltextSin texto completo-
Colección:Artículos
Vista resumida

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.