Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/73914
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Medina, Alfonso | en_US |
dc.contributor.author | Hernández, Enrique | en_US |
dc.contributor.author | Suárez de Lezo, José María | en_US |
dc.contributor.author | Pan, Manuel | en_US |
dc.contributor.author | Melián, Francisco | en_US |
dc.contributor.author | Romero Moreno, Miguel Ángel | en_US |
dc.contributor.author | Marrero, J. | en_US |
dc.contributor.author | Irurita, M. | en_US |
dc.contributor.author | Pavlovic, Djordje | en_US |
dc.date.accessioned | 2020-08-02T16:38:38Z | - |
dc.date.available | 2020-08-02T16:38:38Z | - |
dc.date.issued | 1992 | en_US |
dc.identifier.issn | 1042-3931 | en_US |
dc.identifier.other | WoS | - |
dc.identifier.uri | http://hdl.handle.net/10553/73914 | - |
dc.description.abstract | This article shows the findings observed in a group of 7 patients with short coronary lesions who were treated by a divided (7 mm length) coronary Palmaz-Schatz(TM) stent, in trying to match the length of the stent to that of the treated segment. All of the patients were male and had a mean age of 59 +/- 5 years; 6 had unstable and 1 stable angina. The angiographic length of the lesion was 4.3 +/- 1 mm. The divided stent was successfully deployed in all cases and remained in place without complications. The clinical condition stabilized and all 7 patients were symptom-free 6 months post-hospital discharge. At angiographic follow-up studies, performed before discharge and at 2 and 6 months later, there were no significant changes in the resultant minimal lumen diameter. The stented segment and surrounding areas remained smooth and without intraluminal defects. These observations suggest that a 7 mm length stent is effective in avoiding elastic recoil of discrete coronary lesions. This reduced length could be helpful in: 1) decreasing exposed metallic surface, 2) increasing deliverability and 3) preventing the origin of nearby side-branches to be covered by a standard 15 mm length stent. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Journal of Invasive Cardiology | en_US |
dc.source | Journal of Invasive Cardiology [ISSN 1042-3931], v. 4 (8), p. 389-392, (Octubre 1992) | en_US |
dc.subject | 320501 Cardiología | en_US |
dc.subject.other | Stents | en_US |
dc.subject.other | Palmaz-Schatz Stent | en_US |
dc.title | Divided Palmaz-Schatz(Tm) stent for discrete coronary stenosis | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.identifier.pmid | 10147841 | - |
dc.identifier.scopus | 0026928825 | - |
dc.identifier.isi | A1992JV64900004 | - |
dc.contributor.authorscopusid | 7202723590 | - |
dc.contributor.authorscopusid | 7402296666 | - |
dc.contributor.authorscopusid | 7006785516 | - |
dc.contributor.authorscopusid | 7202544866 | - |
dc.contributor.authorscopusid | 7003549899 | - |
dc.contributor.authorscopusid | 7202430759 | - |
dc.contributor.authorscopusid | 7005957537 | - |
dc.contributor.authorscopusid | 6508272985 | - |
dc.contributor.authorscopusid | 7005198171 | - |
dc.description.lastpage | 392 | en_US |
dc.identifier.issue | 8 | - |
dc.description.firstpage | 389 | en_US |
dc.relation.volume | 4 | en_US |
dc.investigacion | Ciencias de la Salud | en_US |
dc.type2 | Artículo | en_US |
dc.contributor.daisngid | 5831803 | - |
dc.contributor.daisngid | 2740671 | - |
dc.contributor.daisngid | 476437 | - |
dc.contributor.daisngid | 77557 | - |
dc.contributor.daisngid | 4882689 | - |
dc.contributor.daisngid | 156230 | - |
dc.contributor.daisngid | 33557 | - |
dc.contributor.daisngid | 1534651 | - |
dc.contributor.daisngid | 831427 | - |
dc.description.numberofpages | 4 | en_US |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:MEDINA, A | - |
dc.contributor.wosstandard | WOS:HERNANDEZ, E | - |
dc.contributor.wosstandard | WOS:DELEZO, JS | - |
dc.contributor.wosstandard | WOS:PAN, M | - |
dc.contributor.wosstandard | WOS:MELIAN, F | - |
dc.contributor.wosstandard | WOS:ROMERO, M | - |
dc.contributor.wosstandard | WOS:MARRERO, J | - |
dc.contributor.wosstandard | WOS:IRURITA, M | - |
dc.contributor.wosstandard | WOS:PAVLOVIC, D | - |
dc.date.coverdate | Octubre 1992 | en_US |
dc.identifier.ulpgc | Sí | es |
dc.description.scie | SCIE | |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
Appears in Collections: | Artículos |
SCOPUSTM
Citations
5
checked on Mar 30, 2025
WEB OF SCIENCETM
Citations
3
checked on Feb 25, 2024
Page view(s)
99
checked on Sep 21, 2024
Google ScholarTM
Check
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.